REVISION DESCRIPTION

Collection
Hearing Records
Sub-shelf
Zoning
Kind
Hearing Record
Entity
Legislature of the Virgin Islands
Date
2025
Type
20-FT
Pages
5
Text
Native Text

ID. REV. DATE CHK BY APP GK REVISION DESCRIPTION date comm no. DRAWING NO. of PROJECT ADDRESS DRAWING TITLE DOB JOB No.: SHEET LIST: ISSUED FOR CONSTRUCTION 03.02.2025 15:23:34 GENERAL NOTES 15 4I & 4J Estate Joseph and Rosendahl St. Thomas, VI 00802 A-1 A-1 GENERAL NOTES 1. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AT THE SITE AND SHALL BE RESPONSIBLE FOR SAME. IF THERE IS ANY VARIATION IN THE FIELD CONDITIONS FROM THESE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT. 2. IF THE G.C. OR HOMEOWNER ANTICIPATE THAT ANY DEVIATIONS FROM THESE DRAWINGS DURING CONSTRUCTION , THE ARCHITECT MUST BE NOTIFIED. 3. ALL CONTRACTORS SHALL HAVE AND MAINTAIN CONTRACTOR'S LIABILITY PROPERTY DAMAGE INSURANCE AND WORKMEN'S COMPENSATION INSURANCE. ALL PHASES OF CONSTRUCTION SHALL COMPLY TO LOCAL, STATE AND FEDERAL SAFETY LAWS. 4. THE CONTRACTOR AND ALL WORK AND MATERIALS MUST COMPLY WITH ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES. ALL PLUMBING AND HEATING WORK SHALL CONFORM WITH THE LOCAL HEALTH DEPARTMENT REQUIREMENTS AND WITH ALL OTHER APPLICABLE CODES AND ORDINANCES. 5. …

Download the original document · Plain text (TXT) · Browse the archive · How this archive works

Original source: https://legvi.org/committeemeetings/Zoning/STT-CCZP0003-25%204I%20Rem%20and%204J%20Rem%20St%20Joseph%20n%20Rosendahl/13B.%20Models/20-FT/Architectural%20Set.pdf

SHA-256 85462e53a11fb3116b496f08565f194f63e2e283187a205064f6a7312d5a070a

Re-using this document

A proceeding of the Legislature of the Virgin Islands, open to the public under 3 V.I.C. § 881, which reaches any committee of any branch of government and permits the news media to publish what it records.

Our description, tagging, arrangement, extracted text and machine transcripts are released under CC0 1.0. We assert nothing about the document itself.

Archive identifier LF-85462e53a11f

Document text

ID. REV. DATE CHK BY APP GK REVISION DESCRIPTION date comm no. DRAWING NO. of PROJECT ADDRESS DRAWING TITLE DOB JOB No.: SHEET LIST: ISSUED FOR CONSTRUCTION 03.02.2025 15:23:34 GENERAL NOTES 15 4I & 4J Estate Joseph and Rosendahl St. Thomas, VI 00802 A-1 A-1 GENERAL NOTES 1. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AT THE SITE AND SHALL BE RESPONSIBLE FOR SAME. IF THERE IS ANY VARIATION IN THE FIELD CONDITIONS FROM THESE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT. 2. IF THE G.C. OR HOMEOWNER ANTICIPATE THAT ANY DEVIATIONS FROM THESE DRAWINGS DURING CONSTRUCTION , THE ARCHITECT MUST BE NOTIFIED. 3. ALL CONTRACTORS SHALL HAVE AND MAINTAIN CONTRACTOR'S LIABILITY PROPERTY DAMAGE INSURANCE AND WORKMEN'S COMPENSATION INSURANCE. ALL PHASES OF CONSTRUCTION SHALL COMPLY TO LOCAL, STATE AND FEDERAL SAFETY LAWS. 4. THE CONTRACTOR AND ALL WORK AND MATERIALS MUST COMPLY WITH ALL APPLICABLE LOCAL, STATE AND FEDERAL CODES. ALL PLUMBING AND HEATING WORK SHALL CONFORM WITH THE LOCAL HEALTH DEPARTMENT REQUIREMENTS AND WITH ALL OTHER APPLICABLE CODES AND ORDINANCES. 5. THESE SPECIFICATIONS ARE GENERAL IN FORM. THE CONTRACTOR IN APPLYING THEM ASSUMES COMPLETE RESPONSIBILITY FOR THEIR USE, SUBSTITUTIONS, CHANGES AND OMISSIONS. 6. THE ARCHITECT SHALL NOT HAVE CONTROL OR CHARGE OF AND SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 7. THE CONTRACTOR SHALL SUPPLY ALL MATERIALS, FIXTURES, APPLIANCES AND LABOR NECESSARY TO COMPLETE ALL WORK NOTED ON PLANS AND IN ACCORDANCE WITH THE OWNER'S REQUIREMENTS OR AS OTHERWISE NOTED. ALL MATERIAL SHALL BE NEW AND FREE FROM ANY DEFECTS. 8. REMOVE FROM PREMISES ALL RUBBISH AND ACCUMULATED MATERIALS OF WHATEVER NATURE, EXCEPT AS INDICATED BY OWNER. FLOORS SHALL BE LEFT IN A CLEAN, ORDERLY CONDITION ACCEPTABLE TO THE OWNER AND READY FOR OCCUPANCY. 9. ALL WORKMANSHIP AND MATERIALS SHALL BE GUARANTEED FOR ONE YEAR FROM DATE OF OWNER'S ACCEPTANCE UNLESS OTHERWISE NOTED. 10. ALL EXTERIOR OPENINGS SHALL BE PROPERLY FLASHED. PROVIDE COMPLETE WEATHER-STRIPPING OF JAMBS, HEAD AND SILL AT ALL EXTERIOR OPENINGS. 11. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR SITE SAFETY. 1. FURNISH AND INSTALL ALL INSULATION AS SPECIFIED BY THE UCC APPROVED PRESCRIPTIVE PACKAGE LETTER PROVIDED BY THE ARCHITECT WHICH CORRELATES WITH THE BUILDING SECTIONS SHOWN ON THE ARCHITECT'S DRAWINGS. IF THE ARCHITECTURAL DRAWINGS AND PRESCRIPTIVE PACKAGE LETTER ARE CONFLICTING, THE PRESCRIPTIVE PACKAGE LETTER SHALL GOVERN, AND THE G.C. IS TO NOTIFY THE ARCHITECT OF ANY CONFLICTING INFORMATION. ALL FLASH & BATT OR BLANKET TYPE INSULATION SHALL BE AS MANUFACTURED BY OWENS CORNING CORPORATION OR CERTAINTEED CORPORATION OR APPROVED EQUAL. 2. ALL FLASH & BATT INSULATION SHALL HAVE VAPOR BARRIER ON ONE SIDE. ALL BATTS SHALL BE CUT TO LENGTHS REQUIRED FOR INSTALLATION. ALL BATTS SHOULD FIT TIGHTLY BETWEEN STUDS OR JOISTS. INSULATION SHALL BE FASTENED WITH STAPLES THROUGH STAPLING FLANGES EVERY 8 IN. ON BOTH SIDES. NO GAPS SHOULD BE PRESENT ALONG STUDS OF JOISTS OR BETWEEN BATTS. THE FACE OF THE INSULATION SHALL BE AT LEAST 3/4 IN. ABOVE THE UNDERSIDES OF CEILING JOISTS. ALLOW FOR AIR FLOW WHERE NECESSARY. INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. REQUIRED INSULATION R VALUES AS SHOWN ON BUILDING SECTIONS. INSULATION 1. STANDARD GYPSUM BOARD SHALL BE ANSI/ASTM C36; 1/2 IN. OR 5/8 IN. THICK AS INDICATED ON DRAWINGS, MAXIMUM PERMISSIBLE LENGTH; ENDS SQUARE CUT, TAPERED SQUARE EDGES. FIRE RATED GYPSUM BOARD SHALL BE ANSI/ASTM C36; FIRE RESISTIVE TYPE, U.L. RATED; 1/2 IN. OR 5/8 IN. THICK AS INDICATED ON DRAWINGS, MAXIMUM PERMISSIBLE LENGTH; ENDS SQUARE CUT, TAPERED SQUARE EDGES. MOISTURE RESISTANT GYPSUM BOARD SHALL BE ANSI/ASTM C630; 1/2 IN. OR 5/8 IN. THICK AS INDICATED ON DRAWINGS, MAXIMUM PERMISSIBLE LENGTH; ENDS SQUARE CUT, TAPERED SQUARE EDGES. ALL GYPSUM BOARD SHALL BE SCREWED NOT NAILED. 2. WATER-RESISTANT GYPSUM BACKING BOARD. GYPSUM BOARD USED AS THE BASE OR BACKER FOR ADHESIVE APPLICATION OF CERAMIC TILE OR OTHER REQUIRED NONABSORBENT FINISH MATERIAL SHALL CONFORM TO ASTM C 1396, C 1178 OR C 1278. USE OF WATER-RESISTANT GYPSUM BACKING BOARD SHALL BE PERMITTED ON CEILINGS. WATER-RESISTANT GYPSUM BOARD SHALL NOT BE INSTALLED OVER A CLASS I OR II VAPOR RETARDER IN A SHOWER OR TUB COMPARTMENT. CUT OR EXPOSED EDGES, INCLUDING THOSE AT WALL INTERSECTIONS, SHALL BE SEALED AS RECOMMENDED BY THE MANUFACTURER. LIMITATIONS: WATER-RESISTANT GYPSUM BACKING BOARD SHALL NOT BE USED WHERE THERE WILL BE DIRECT EXPOSURE TO WATER, OR IN AREAS SUBJECT TO CONTINUOUS HIGH HUMIDITY. 3- CERAMIC TILE: BACKER BOARDS MATERIALS USED AS BACKERS FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL PANELS IN SHOWER AREAS SHALL BE OF MATERIALS LISTED AND INSTALLED IN ACCORDANCE WITH THE MANUFACTURER S RECOMMENDATIONS. GYPSUM BOARD MATERIALS 1. WINDOW MANUF. TO BE SELECTED BY OWNER. SEE SCHEADULE FOR DOOR/WINDOW SCHEDULE. G.C. TO SUBMIT PLANS, ELEVATION AND WINDOW SCHEDULE TO WINDOW SUPPLIER FOR FORMAL PURCHASE QUOTE AND ROUGH OPENING SCHEDULE THAT CORRELATES WITH WINDOW SIZES DESIGNATIONS ON WINDOW SCHEDULE. G.C. TO UTILIZE ROUGH OPENINGS AS PROVIDED BY WINDOW SUPPLIER'S PURCHASE QUOTE AND FRAME-OUT WINDOWS ACCORDINGLY. PRIOR TO PURCHASING OF WINDOWS, G.C. SHALL SUBMIT WINDOW PURCHASE QUOTE TO ARCHITECT FOR REVIEW AND SIGN-OFF. IF G.C. OR OWNER FAILS TO SUBMIT WINDOW PURCHASE QUOTE TO ARCHITECT FOR REVIEW, ARCHITECT IS NOT LIABLE FOR ANY ERRORS OR OMISSION THAT EITHER ORIGINATED FROM THE WINDOW PURCHASE QUOTE OR FROM ARCHITECT'S ORIGINAL DRAWINGS. PROVIDE SCREENS AT OPERABLE WINDOW UNITS AT GLIDING EXTERIOR DOORS. PROVIDE DOUBLE PANE, LOW-E GLASS. WHITE VINYL EXTERIOR, NATURAL PINE INTERIOR. PROVIDE STANDARD FINISH HARDWARE. TEMPERED GLASS SHALL BE REQUIRED IN THE FOLLOWING CIRCUMSTANCES: 1) WHEN WINDOWS ARE LESS THAN 18" TO THE FLOOR. 2) WHEN A DOOR SWING IS CLOSER THAN 24" TO A WINDOW. 3) WHEN A WINDOW IS IN A STAIRWELL OR STAIRCASE. 4) WHEN A WINDOW IS ABOVE A TUB OR IN A SHOWER. 5) WHEN A WINDOW IS ABOVE A BUILT-IN BENCH SEAT. WINDOWS 1. IT IS THE ARCHITECTS RECOMMENDATION THAT ALL INTERIOR DOORS ARE SOLID WOOD DOORS, STAINED AND VARNISHED. OWNER TO CONSIDER LOOKING FOR DOOR STYLE AND WOOD SPECIES AT NICKSBUILDING.COM OR EQUAL. ALL CLOSET DOORS TO BE HOLLOW CORE DOORS. 2. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL MATERIAL, EQUIPMENT, TOOLS, TRANSPORTATION, ACCESSORIES, AND RELATED ITEMS NECESSARY TO COMPLETE THE WORK OF THIS SECTION. 3. G.C. SHALL PROVIDE IN HIS BASE BID A REASONABLE ALLOWANCE FOR ALL INTERIOR DOORS., ALL INTERIOR DOORS AT THE 1ST FLOOR SHALL BE AS PER G.C. CONTRACT. ALL SOLID DOORS TO BE SOLID MASONITE OR SOLID WOOD. INTERIOR DOORS 1. PROVIDE ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY TO COMPLETE ALL EXCAVATING, BACKFILL AND GRADING WORK AS INDICATED ON THE DRAWINGS AND AS SPECIFIED HEREIN. 2. EXCAVATE TO LEVELS SHOWN OR AS REQUIRED TO REACH REQUIRED BEARING SOIL FOR ALL FOOTINGS, FOUNDATIONS, COLUMNS, WALLS, PIERS, PITS, ETC.. CARE SHALL BE TAKEN NOT TO DISTURB EARTH OR EXCAVATE BELOW DEPTHS INDICATED ON THE DRAWINGS. EXCAVATION SHALL EXTEND A SUFFICIENT DISTANCE FROM WALLS AND FOOTINGS TO ALLOW FOR FORMS, INSTALLATION OF SERVICES AND FOR INSPECTION. 3. THE CONTRACTOR SHALL PROVIDE AND OPERATE ALL PUMPS AND OTHER EQUIPMENT NECESSARY TO DRAIN AND KEEP ALL EXCAVATIONS REASONABLY FREE FROM WATER. 4. FOUNDATION APPROVAL TO BE DEPENDENT UPON PROPER FOUNDATION BRACING (TEMPORARY OR ATTACHED FLOOR FRAMING) AFTER APPROVAL OF FOUNDATIONS AND OTHER WORK, BACKFILL AGAINST SAME USING APPROVED EXCAVATED MATERIALS, FREE FROM RUBBISH, VEGETABLE MATTER AND OTHER OBJECTIONABLE MATTER. INSTALL BACKFILL IN LAYERS NOT MORE THAN 6 IN. THICK, TAMPING EACH LAYER BEFORE INSTALLING SUCCEEDING LAYER. BRING BACKFILL TO PROPER ELEVATIONS TO RECEIVE WORK WHICH IS TO BE INSTALLED THEREON. 5. REMOVE TOP SOIL TO ITS FULL DEPTH WITHIN THE AREA OF THE "EXTENT OF WORK" AND UNDER ALL PROPOSED WALKS, DRIVES, ETC., AND STACK CAREFULLY IN LOCATION WHERE DIRECTED ON SITE. 6. ALL OUTSIDE AREAS OF THE BUILDING, UNLESS OTHERWISE INDICATED, WITHIN THE GRADING LINES SHALL BE GRADED TO ELEVATIONS BELOW THE FINISH GRADES SHOWN, TO ALLOW FOR FILL AND FINISHED MATERIALS. ALL GRADING MUST AVOID LEAVING PONDS OR LARGE COLLECTIONS OF WATER. 7. PROVIDE 3/4J" Q.P. UNDER DRIVEWAY AND ALL PAVER WALKWAYS 8. SOIL COMPACTION UNDER ALL FOOTINGS AND GRADE BEAMS, SPREAD FOOTING, ETC., SHALL BE DESIGNED TO SUSTAIN A SOIL BEARING PRESSURE OF 3000 PSI UNDER FOOTING. EXCAVATING, FILLING AND GRADING 1. PROVIDE ALL LABOR, MATERIAL, EQUIPMENT AND SERVICES NECESSARY TO COMPLETE ALL CONCRETE AND MASONRY WORK AS INDICATED ON THE DRAWINGS AND AS SPECIFIED HEREIN FOR WALL FOOTINGS, CONC. FLOOR SLABS AND STEPS, CONCRETE SIDEWALKS AND CURBS, ALL FORMS AND REINFORCING REQUIRED, ALL EXTERIOR AND INTERIOR MASONRY WALLS AND PARTITIONS, ALL ANCHOR BOLTS, ALL TIES, REINFORCING, AND ANCHORS REQUIRED FOR SECURING ALL MASONRY WORK TOGETHER, GRAVEL BASE AND VAPOR BARRIER UNDER CONCRETE SLABS, PRE-CAST CONCRETE SILLS WHERE REQUIRED, POINTING AND CLEANING DOWN ALL MASONRY WORK EXPOSED TO VIEW, DAMP PROOFING CONCRETE WALLS BELOW GRADE, AND ALL OTHER LABOR AND MATERIALS AS MAY BE REASONABLY INFERRED AS NEEDED TO MAKE THE WORK UNDER THIS SECTION COMPLETE. 2. CONTRACTOR TO REMOVE EXISTING FOUNDATION WALLS THAT IMPEED THE NEW FOOTPRINT FOR NEW FOUNDATION WALLS, FOOTINGS, SLABS, ETC. 3. CONCRETE BLOCK, LOAD BEARING UNITS SHALL CONFORM TO THE CURRENT EDITION OF THE ASTM SPECIFICATIONS FOR CONCRETE UNITS, DESIGNATION C-90. 4. PREMOLDED JOINT FILLERS USED WHEREVER EDGES OF CONCRETE SLABS ABUTS A VERTICAL SURFACE SHALL BE RIGID NON-EXPANDING APPROVED TYPE PRE-MOLDED ASPHALT IMPREGNATED FIBERBOARD, 1/2 IN. THICK. 5. MASONRY WALL REINFORCEMENT SHALL BE DUR-O-WALL TRUSS DESIGNED OR APPROVED EQUAL REINFORCEMENT. REINFORCING SHALL BE NEW DEFORMED STEEL BARS CONFORMING TO THE LATEST REQUIREMENTS OF ASTM A-15. DEFORMATIONS SHALL BE IN ACCORDANCE WITH THE ASTM A-305. FABRIC REINFORCEMENT SHALL BE WELDED WIRE FABRIC CONFORMING TO THE LATEST EDITION OF THE ASTM A-185. 6. VAPOR BARRIER UNDER SLABS ON GRADE SHALL BE POLYETHYLENE 6 MILS OR APPROVED EQUAL. 7. GRAVEL FOR POROUS FILL SHALL BE CLEAN AND WELL GRADED. 8. CONCRETE MIX SHALL BE DESIGNED TO SECURE A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 3500 PSI ALL IN ACCORDANCE WITH THE PROCEDURE SET FORTH BY THE ASTM. THE CONSISTENCY OF THE MIX SHALL BE THAT REQUIRED FOR THE SPECIFIC PLACING CONDITIONS AND METHODS OF PLACEMENT AND ORDINARILY THE SLUMP SHALL BE BETWEEN 2 IN. AND 3 IN. BUT IN NO CASE MORE THAN 5 IN. 9. SOIL UNDER SLABS ON GROUND SHALL BE COMPACTED TO A FIRM, UNYIELDING SURFACE. NO CONCRETE SHALL BE LAID ON FROZEN SOIL AND ADEQUATE PROTECTION AGAINST FROST ACTION SHALL BE PLACED ON EARTH WHICH HAS BEEN BACKFILLED OR OTHERWISE DISTURBED. 10. CONCRETE FOOTINGS ARE REQUIRED UNDER ALL MASONRY WALLS. UNDER ALL FOOTINGS,GRADE BEAMS, AND SPREAD FOOTINGS, SOIL COMPACTION SHALL BE ADEQUATE ENOUGH TO SUPPORT A SOIL BEARING PRESSURE OF 3000 PSI UNDER FOOTING. 11. CONSTRUCTION JOINTS ARE TO BE AVOIDED IF POSSIBLE. HOWEVER, WHERE REQUIRED AS TO THE END OF THE DAY'S POUR, CONSTRUCTION JOINTS WILL BE ALLOWED. AT CONSTRUCTION JOINTS, KEYWAYS SHALL BE CAST IN THE CONCRETE AND WHERE CONCRETE IS REINFORCED, THE STEEL SHALL EXTEND THROUGH THE JOINT. 12. CONCRETE BLOCK, IF APPLICABLE, SHALL BE AS SPECIFIED HEREIN OF THICKNESSES AND TEXTURES AS INDICATED. BLOCK SIZES SPECIFIED ARE NOMINAL SIZES. BLOCK SHALL BE MANUFACTURED IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE NATIONAL CONCRETE MASONRY ASSOCIATION. ALL BLOCK WORK SHALL BE LAID IN A FULL BED OF MORTAR IN A WORKMANLIKE MANNER WITH VERTICAL AND HORIZONTAL JOINTS TOOLED UP BOTH INTERIOR AND EXTERIOR. ALL BROKEN AND OTHERWISE DEFECTIVE BLOCKS SHALL BE DISCARDED. WHERE BLOCK WORK INTERSECTS OTHER BLOCK WORK, THE INTERSECTION SHALL BE BONDED AT EACH COURSE AVOIDING CONTINUOUS VERTICAL JOINTS. CONTROL JOINTS SHALL BE FORMED WHERE INDICATED ON DRAWINGS. PRE- FORMED JOINT FILLERS SHALL BE INSTALLED AT CONTROL JOINTS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATION. ALL BLOCK WORK SHALL BE REINFORCED WITH METAL TRUSS TYPE REINFORCING, SPACE AT 16 IN. O.C. VERTICALLY. WHERE NORMAL REINFORCING DOES NOT OCCUR AT A COURSE DIRECTLY OVER DOOR AND WINDOW HEADS, ADD EXTRA REINFORCEMENT. LENGTH TO BE AT LEAST 4 FT. 0 IN. MORE THAN OPENING. 13. BLOCK SHALL NOT BE LAID WHEN THE TEMPERATURE IS BELOW 40 DEGREES F., EXCEPT WITH PERMISSION OF THE ARCHITECT AND PROVIDED THAT THE CONTRACTOR PROVIDES A SATISFACTORY METHOD OF HEATING MATERIALS BEFORE LAYING. ALL MASONRY SHALL BE ADEQUATELY PROTECTED FROM DAMAGE BY STORMS AND FROST, AND MAINTAINED AT A TEMPERATURE ABOVE FREEZING UNTIL THE MORTAR IS SET. 14. ALL CONCRETE BELOW GRADE SHALL BE DAMP PROOFED ON THE EXTERIOR FACE WITH APPROVED MATERIALS. 15. FOR EACH DIFFERENT CONCRETE MASONRY UNIT, TEST UNIT FOR STRENGTH, ABSORPTION & MOISTURE CONTENT PER ASTM C 140. MANUFACTURERS SUBJECT TO COMPLIANCE WITH REQUIREMENTS, BY ONE OR MORE OF THE FOLLOWING )OR APPROVED EQUAL): RINKLER MATERIALS, H&B, APG CONCRETE BLOCK. 16. BEARING ON WALLS SHALL BE AS REQUIRED TO DISTRIBUTE THE LOAD BUT NOT LESS THAN FOUR INCHES. CONCRETE AND MASONRY WORK STAIRS: STAIRS SHALL BE FABRICATED IN ACCORDANCE WITH latest new jersey ucc (and irc) code AND DELIVERED TO THE SITE READY FOR INSTALLATION. BEARING AND FASTENING SHALL BE IN ACCORDANCE WITH THE FABRICATORS REQUIREMENTS AND APPLICABLE CODES. 1. FLAT ROOF SHALL BE 2" WATERPROOF ROOF SCREED. 2. EXPOSED FLASHINGS AND COUNTER FLASHINGS SHALL BE COPPER, CONCEALED FLASHINGS MAY BE OF OTHER SUITABLE CORROSION RESISTANT MATERIAL. 3. INSTALL ALL ROOFING MATERIAL AND FLASHING IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. INSTALL ROOF-TO-WALL FLASHINGS AT ALL INTERSECTIONS. ON SHINGLE ROOFS SHEET METAL INSTALL FLASHING IN "STEP" FASHION. IN MASONRY WALLS INSTALL COUNTER-FLASHING EMBEDDED IN MASONRY. FLASH PIPES PROJECTING THROUGH ROOF WITH ONE PIECE SHEET METAL FORMING A FLANGE WHICH EXTENDS AT LEAST 6 IN. ON ALL SIDES. 4. ALL OTHER SHEET METAL ITEMS AND ACCESSORIES, - GUTTERS, DOWNSPOUTS, SHALL BE DESIGNED AND INSTALLED BY THE GUTTER SUBCONTRACTOR ROOFING 1. TO PREPARE FOR FLOOR FINISH, FLOORING SHALL BE SANDED, IF REQUIRED, TO OBTAIN A SMOOTH SURFACE. ALL SCRATCHES, DENTS, GOUGES, ETC. SHALL BE REPLACED OR REPAIRED WITH FILLER AS PER THE MANUFACTURER'S RECOMMENDATION. FINISH ALL WOOD FLOORS WITH POLYURETHANE IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. WHERE REQUIRED, STAIN SPECIFIC ROOMS AS NOTED IN ROOM FINISH SCHEDULE. 2. FURNISH ALL LABOR AND MATERIAL NECESSARY FOR THE COMPLETE PAINTING AND CAULKING OF ALL NEW WORK ON INTERIOR AND EXTERIOR OF BUILDING. PAINTED SURFACES, BOTH EXTERIOR AND INTERIOR, SHALL RECEIVE AT LEAST TWO COATS OVER PRIMER EXCEPT WHEN PAINT MANUF. SUGGESTS THAT ONE COAT IS ACCEPTABLE. ALL PAINT COLORS AND INTERIOR STAINS SHALL MATCH COLORS OF BENJAMIN MOORE. ALL PAINT SHALL BE BY BENJAMIN MOORE OR APPROVED EQUAL. SURFACES, WHERE NECESSARY, SHALL BE PROPERLY PREPARED FOR FINISH PAINTING BY WASHING, SCRAPING, WIRE BRUSHING, OR SANDING. PAINT SHALL BE APPLIED ONLY TO SURFACES WHICH ARE ABSOLUTELY DRY AND FREE FROM GREASE, OIL, DIRT, RUST, SCALE, OR LOOSE MATERIAL. COLORS TO BE SELECTED BY OWNER. PAINTING 1. INSTALL ALL BATHROOM FIXTURES AND BATHROOM ACCESSORIES AS PURCHASED BY HOMEOWNER. TOILET ACCESSORIES 310 VI CODE 2024 (IRC) INTERNATIONAL RESIDENTIAL CODE 2021 (IMC) INTERNATIONAL MECHANICAL CODE 2023 (NEC) NATIONAL ELECTRIC CODE 2024 (UPC) UNIFORM PLUMBING CODE APPLICABLE CODES: Range Refrigerator UP DN GENERAL NOTES: 1. INTERIOR DIMENSIONS ARE TAKEN FROM FINISHED GYP. SURFACES. 2. ALL UNTAGGED PARTITIONS ARE 2x4 NON-LOAD BEARING INTERIOR PARTITIONS. -REFER TO PARTITION TYPES 3. ALL INTERIOR DOORS ARE SHOWN 4" FROM HINGED CORNER, OR CENTERED ON WALL, U.N.O. 4. PROVIDE MECHANICAL VENTILATION SYSTEM FOR ALL INTERIOR BATHROOMS WHICH EXHAUSTS AIR WITHOUT RE-CIRCULATION TO ANY SPACE AND VENTILATION FOR ALL DRYERS AS SEEN ON FLOOR PLANS. 5. PROVIDE 34" - 38" HIGH HANDRAILS AT ALL STAIRS - INSTALLED PER MANUFACTURER'S SPECS. COMMON SUMBOLS: P1 WALL TAG R-01 DOOR TAG ALIGN X A4.0 SECTION CUT M1 A5.0 DETAIL TAG CL CENTERLINE A WINDOW TAG WALL LEGEND: - PROPOSED WOOD FRAME WALL - PROPOSED WOOD FRAME PARTITION - PROPOSED CONCRETE WALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A NET CLEAR OPENING OF NOT LESS THAN 5.7 SQUARE FEET (0.530 M2). THE NET CLEAR OPENING DIMENSIONS REQUIRED BY THIS SECTION SHALL BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE AND RESCUE OPENING FROM THE INSIDE. THE NET CLEAR HEIGHT OPENING SHALL BE NOT LESS THAN 24 INCHES (610 MM) AND THE NET CLEAR WIDTH SHALL BE NOT LESS THAN 20 INCHES (508 MM). WHERE A WINDOW IS PROVIDED AS THE EMERGENCY ESCAPE AND RESCUE OPENING, IT SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 INCHES (1118 MM) ABOVE THE FLOOR; WHERE THE SILL HEIGHT IS BELOW GRADE, IT SHALL BE PROVIDED WITH A WINDOW WELL IN ACCORDANCE WITH SECTION R310.2.3. 2015 INTERNATIONAL RESIDENTIAL CODES R310.2.1 W1 EXTERIOR WALL (SIDING FINISH) 1 INTERIOR FINISH BY OWNER 2 1/2" GYPSUM BOARD 3 6" ICF BLOCK WALL 4 1X3 WOOD FURRING 5 VERTICAL SIDING FINISH (BY OWNER) WALL ASSEMBLIES W1w EXTERIOR WATERPROOF WALL (SIDING FINISH) 1 INTERIOR FINISH BY OWNER 2 VAPOUR BARRIER 3 1/2" WATERPROOF GYPSUM BOARD 4 6" ICF BLOCK WALL 5 1X3 WOOD FURRING 6 HORISONTAL SIDING FINISH (BY OWNER) W2 EXTERIOR WALL (STUCCO FINISH) 1 INTERIOR FINISH BY OWNER 2 1/2" GYPSUM BOARD 3 6" ICF BLOCK WALL 4 SCRATCH COAT WITH MESH 5 STUCCO FINISH W3 EXTERIOR WALL (UNDERGROUND) 1 INTERIOR FINISH BY OWNER 2 1/2" GYPSUM BOARD 3 8" ICF BLOCK WALL 4 WATERPROOF MEMBRANE ROOF ASSEMBLIES 1 REFLECTIVE COATING 2 ROOF UNDERLAYMENT PER ROOFING MANUFACTURERS INSTALLATION RECOMENDATIONS (ICE & WATER SHIELD) (from the lowest edges of all roof surfaces to a point at least 36 inches inside the exterior wall line of the building.) 3 ROOF SHEATHING PER STRUCTURAL 4 JOIST (SEE STRUCTURALS) WITH BATT INSULATION R-49 5 1/2" GYPSUM BOARD R1 P1 TYPICAL INTERIOR PARTITION 1 INTERIOR FINISH BY OWNER 2 1/2" GYPSUM BOARD 3 2x4" FRAMING 4 1/2" GYPSUM BOARD 5 INTERIOR FINISH BY OWNER PARTITION ASSEMBLIES P2 TYPICAL WATERPROOF INTERIOR PARTITION 1 INTERIOR FINISH BY OWNER 2 1/2" WATERPROOF GYPSUM BOARD 3 6mil POLY VAPOUR BARRIER 4 2x4" FRAMING 5 6mil POLY VAPOUR BARRIER 6 1/2" WATERPROOF GYPSUM BOARD 7 INTERIOR FINISH BY OWNER FLOOR ASSEMBLIES F1 F2 1 1" VINYL FLOORING 2 1" FRAMING 3 WATERPROF MEMBRANE 4 CONCRETE SLAB 1 CERAMIC TILE 2 GLUE MASTIC 3 WATER PROOFING 4 CONCRETE SLAB 1 1" VINYL FLOORING 2 1" FRAMING 3 WATER PROOFING 4 OSB SHEATHING 5 WOOD JOISTS SEE STRUCTURAL 1 CERAMIC TILE 2 GLUE MASTIC 3 WATER PROOFING 4 OSB SHEATHING 5 WOOD JOISTS SEE STRUCTURAL F3 F4 W4 INTERIOR BEARING WALL 1 INTERIOR FINISH BY OWNER 2 1/2" GYPSUM BOARD 3 2x6" FRAMING 4 1/2" GYPSUM BOARD 5 INTERIOR FINISH BY OWNER W5 INTERIOR WATERPROOF BEARING WALL 1 INTERIOR FINISH BY OWNER 2 1/2" WATERPROOF GYPSUM BOARD 3 6mil POLY VAPOUR BARRIER 4 2x6" FRAMING 5 6mil POLY VAPOUR BARRIER 6 1/2" WATERPROOF GYPSUM BOARD 7 INTERIOR FINISH BY OWNER 7' - 11" 30' - 8" 5' - 6 1/2" 5' - 6" 5' - 6" 5' - 6 1/2" 28' - 5" 8' - 0" 10' - 1 1/2" 13' - 0" 4' - 0" 3' - 0" 8' - 0" 2' - 6 3/4" 7' - 11 1/4" 9' - 11" 20' - 0" 4' - 4 1/2" 5' - 0" 3' - 1" 3' - 1" 7' - 0" 9' - 11" 173.0 ft² GREAT ROOM 123.5 ft² DINING 13.5 ft² LAUNDRY 15.4 ft² WC 30.4 ft² STAIRCASE 99.2 ft² KITCHEN 99.2 ft² LIVING ROOM 7' - 11" 30' - 8" 22' - 1" 20' - 0" DECK ABOVE DECK ABOVE DECK ABOVE 38' - 7" 38' - 7" 22' - 1" W3 W2 W2 W2 WD-1 WD-1 D1 D2 D3 P1 P2 P1 W5 P2 OPENING 22' - 1" 1 A-4 F1 F1 F1 F1 F1 F2 2 A-4 32PSI 4'' SLAB-ON-GRADE 5%-8% air entrainment REINF.WITH #5@10”C/C on 6'' CRUSHED GRAWEL 10' - 1 1/2" 7' - 7 1/2" 3' - 6" 2' - 6" 14' - 7 1/2" 5' - 0" 8' - 0" 30' - 7" 8' - 0" 30' - 7" 5' - 6 1/2" 5' - 6" 5' - 6" 5' - 6 1/2" 22' - 1" 3' - 6 1/2" 5' - 10 1/2" 6' - 0" 6' - 8" 69.8 ft² LOFT 40.0 ft² BATHROOM DECK 2' - 3" 8' - 0" 2' - 0" 8' - 0" 9' - 4 1/2" 8' - 3 1/2" 11' - 4" 2' - 6" 5' - 0" 2' - 6" 12' - 0" 5' - 0" 10' - 0" 5' - 0" 5' - 0" 2' - 11" 2' - 10 1/2" 2' - 6" 2' - 7" 5' - 4 1/2" 3' - 4 1/2" 2' - 0" 4' - 0" 4' - 0" 6' - 0" 1' - 7 1/2"2' - 11 1/2" 7' - 0 1/2" 10.0 ft² CLOSET 10.0 ft² CLOSET 106.5 ft² BEDROOM 84.7 ft² BEDROOM 120.0 ft² MASTER BEDROOM 40.0 ft² MASTER BATHROOM 22.5 ft² CLOSET WD-2 D5 D5 D4 D4 D2 D2 D4 D4 D4 D2 D2 WD-1 WD-1 WD-1 P1 P1 P1 P1 P1 P1 P2 P2 P1 P1 P2 P2 P1 W1 W1 W1 W1 1 A-4 F3 F3 F3 F3 F4 F4 2 A-4 38' - 7" 38' - 7" 22' - 1" F3 1 A-4 0" / 12" DECK DRAINAGE HOLE 7' - 11 1/2" 30' - 10 3/4" 22' - 3 1/2" 7' - 11 1/2" 30' - 10 3/4" 22' - 4 3/4" 2 A-4 ID. REV. DATE CHK BY APP GK REVISION DESCRIPTION date comm no. DRAWING NO. of PROJECT ADDRESS DRAWING TITLE DOB JOB No.: SHEET LIST: ISSUED FOR CONSTRUCTION 03.02.2025 15:23:35 BUILDING PLAN 15 4I & 4J Estate Joseph and Rosendahl St. Thomas, VI 00802 A-2 A-2 WINDOW SCHEDULE WINDOW # OPERATION TYPE W H HEAD HT. U VALUE NOTES WD-1 32.0" 58.0" 94.0" WD-2 SIDE HUNG 38.0" 18.0" 96.0" DOOR SCHEDULE DOOR # WIDTH HEIGTH THICK NESS MAT'L FRAME THRES HOLD WALL TYPE WALL RATING DOOR RATING HARDWARE NOTES D1 33.7" 84.0" 1.8" WD W DEADBOLT ENTRY DOOR D2 52.0" 81.0" 1.8" WD W D3 30.0" 81.0" 1.8" WD W D4 30.0" 81.0" 1.8" WD W D5 60.0" 94.0" 1.8" WD W DEADBOLT PATIO DOOR 1/4" = 1'-0" A-2 1 1ST FLOOR PROPOSED PLAN 1/4" = 1'-0" A-2 2 2ND FLOOR PLAN 1/4" = 1'-0" A-2 3 ROOF PLAN 1ST FLOOR LEVEL 0' - 0" 1ST FLOOR LEVEL 0' - 0" GRADE -0' - 6" GRADE -0' - 6" 2ND FLOOR LEVEL 10' - 0" 2ND FLOOR LEVEL 10' - 0" T.O.S.2 18' - 9" T.O.S.2 18' - 9" T.O.S.1 8' - 9" T.O.S.1 8' - 9" T.O. ROOF 20' - 0" T.O. ROOF 20' - 0" PARAPETE LEVEL 22' - 0" PARAPETE LEVEL 22' - 0" 4' - 10" 5' - 2" 4' - 10" 3' - 0" 4' - 10" 13' - 0" 22' - 6" 2' - 0" 1' - 3" 8' - 9" 1' - 3" 8' - 9" 0' - 6" 2' - 0" 1' - 3" 8' - 9" 1' - 3" 8' - 9" 0' - 6" 22' - 6" STUCCO FINISH VINYL SIDING FINISH 1ST FLOOR LEVEL 0' - 0" 1ST FLOOR LEVEL 0' - 0" GRADE -0' - 6" GRADE -0' - 6" 2ND FLOOR LEVEL 10' - 0" 2ND FLOOR LEVEL 10' - 0" T.O.S.2 18' - 9" T.O.S.2 18' - 9" T.O.S.1 8' - 9" T.O.S.1 8' - 9" T.O. ROOF 20' - 0" T.O. ROOF 20' - 0" PARAPETE LEVEL 22' - 0" PARAPETE LEVEL 22' - 0" 10' - 0" 7' - 9 1/2" 8' - 6" 8' - 0" 1' - 6" 0' - 6" 8' - 9" 1' - 3" 8' - 9" 1' - 3" 2' - 0" 22' - 6" 0' - 6" 8' - 9" 1' - 3" 8' - 9" 1' - 3" 2' - 0" 22' - 6" VINYL SIDING FINISH RAILING 42" 1ST FLOOR LEVEL 0' - 0" 1ST FLOOR LEVEL 0' - 0" GRADE -0' - 6" GRADE -0' - 6" 2ND FLOOR LEVEL 10' - 0" 2ND FLOOR LEVEL 10' - 0" T.O.S.2 18' - 9" T.O.S.2 18' - 9" T.O.S.1 8' - 9" T.O.S.1 8' - 9" T.O. ROOF 20' - 0" T.O. ROOF 20' - 0" PARAPETE LEVEL 22' - 0" PARAPETE LEVEL 22' - 0" 3' - 6 1/2" 10' - 0" 2' - 0" 1' - 3" 8' - 9" 1' - 3" 8' - 9" 0' - 6" 22' - 6" 2' - 0" 1' - 3" 8' - 9" 1' - 3" 8' - 9" 0' - 6" 22' - 6" RAILING 42" STUCCO FINISH VINYL SIDING FINISH 1ST FLOOR LEVEL 0' - 0" 1ST FLOOR LEVEL 0' - 0" GRADE -0' - 6" GRADE -0' - 6" 2ND FLOOR LEVEL 10' - 0" 2ND FLOOR LEVEL 10' - 0" T.O.S.2 18' - 9" T.O.S.2 18' - 9" T.O.S.1 8' - 9" T.O.S.1 8' - 9" T.O. ROOF 20' - 0" T.O. ROOF 20' - 0" PARAPETE LEVEL 22' - 0" PARAPETE LEVEL 22' - 0" 2' - 0" 1' - 3" 8' - 9" 1' - 3" 8' - 9" 0' - 6" 22' - 6" 2' - 0" 1' - 3" 8' - 9" 1' - 3" 8' - 9" 0' - 6" 22' - 6" 3' - 6 1/2" 10' - 0" RAILING 42" STUCCO FINISH VINYL SIDING FINISH ID. REV. DATE CHK BY APP GK REVISION DESCRIPTION date comm no. DRAWING NO. of PROJECT ADDRESS DRAWING TITLE DOB JOB No.: SHEET LIST: ISSUED FOR CONSTRUCTION 03.02.2025 15:23:43 BUILDING ELEVATIONS 15 4I & 4J Estate Joseph and Rosendahl St. Thomas, VI 00802 A-3 A-3 1/4" = 1'-0" A-3 4 FRONT ELEVATION 1/4" = 1'-0" A-3 1 REAR ELEVATION 1/4" = 1'-0" A-3 2 LEFT ELEVATION 1/4" = 1'-0" A-3 3 RIGHT ELEVATION 1ST FLOOR LEVEL 0' - 0" 1ST FLOOR LEVEL 0' - 0" GRADE -0' - 6" GRADE -0' - 6" 2ND FLOOR LEVEL 10' - 0" 2ND FLOOR LEVEL 10' - 0" T.O. FOOTING -1' - 6" T.O. FOOTING -1' - 6" B.O. FOOTING -2' - 6" B.O. FOOTING -2' - 6" T.O.S.2 18' - 9" T.O.S.2 18' - 9" T.O.S.1 8' - 9" T.O.S.1 8' - 9" T.O. ROOF 20' - 0" T.O. ROOF 20' - 0" PARAPETE LEVEL 22' - 0" PARAPETE LEVEL 22' - 0" 0" 12" 106.5 ft² BEDROOM 10.0 ft² CLOSET 69.8 ft² LOFT 120.0 ft² MASTER BEDROOM 99.2 ft² KITCHEN 15.4 ft² WC 13.5 ft² LAUNDRY 173.0 ft² GREAT ROOM D2 D3 D4 D4 WD-1 D1 D5 RAILING 42" DECK JOISTS SEE STRUCTURAL JOISTS SEE STRUCTURAL JOISTS SEE STRUCTURAL WITH BATT INSULATION R-49 2' - 0" 1' - 3" 8' - 9" 1' - 3" 8' - 9" 0' - 6" 1' - 0" 1' - 0" 24' - 6" 1' - 8 3/4" 7' - 0 1/4" 8' - 9" 3' - 0" 4' - 10" 0' - 11" 8' - 9" 8' - 9" 7' - 9 1/2" 0' - 11 1/2" 2' - 0" 27' - 6" 2' - 0" 7' - 4 3/4" 2' - 0" 2' - 0" 1' - 3" 8' - 9" 1' - 3" 8' - 9" 0' - 6" 1' - 0" 1' - 0" 24' - 6" 2 A-4 CONCRETE SLAB WITH 3" XPS ON 6" CRUSHED GRAWEL P1 P2 P1 P1 P1 P1 W1 W1 W2 W3 R1 F3 F1 2' - 0" A-4 4 S-3 4 1ST FLOOR LEVEL 0' - 0" 1ST FLOOR LEVEL 0' - 0" GRADE -0' - 6" GRADE -0' - 6" 2ND FLOOR LEVEL 10' - 0" 2ND FLOOR LEVEL 10' - 0" T.O. FOOTING -1' - 6" T.O. FOOTING -1' - 6" B.O. FOOTING -2' - 6" B.O. FOOTING -2' - 6" T.O.S.2 18' - 9" T.O.S.2 18' - 9" T.O.S.1 8' - 9" T.O.S.1 8' - 9" T.O. ROOF 20' - 0" T.O. ROOF 20' - 0" PARAPETE LEVEL 22' - 0" PARAPETE LEVEL 22' - 0" 1 A-4 D2 D4 D4 D2 84.7 ft² BEDROOM 106.5 ft² BEDROOM 173.0 ft² GREAT ROOM 8' - 9" 8' - 9" 8' - 9" 8' - 9" 2' - 0" 19' - 0" 2' - 0" 2' - 0" 1' - 3" 8' - 9" 1' - 3" 8' - 9" 0' - 6" 1' - 0" 1' - 0" 24' - 6" 2' - 0" 1' - 3" 10' - 0" 0' - 3" 8' - 6" 0' - 6" 1' - 0" 1' - 0" 24' - 6" TJI 5 60 11.875" @16" C/C MAX 2"X12" @16"C/C WITH BATT INSULATION R-49 4" CONCRETE SLAB WITH 3" XPS ON 6" CRUSHED GRAWEL R1 F3 P1 W1 W2 W2 W1 F1 A-4 5 T.O.S.2 18' - 9" T.O. ROOF 20' - 0" PARAPETE LEVEL 22' - 0" CONCRETE LINTEL FIBER CANT TWO LAYER ROOFFING MEMRANE TJI 5 60 11.875" @16" C/C MAX BATT INSULATION R-49 2"X2" METAL CAP 6" ICF WALL T.O.S.2 18' - 9" T.O. ROOF 20' - 0" PARAPETE LEVEL 22' - 0" LEADGER 2"X12" W 5/8" A.B. @24" C/C 4" EMB METAL CAP FIBER CANT TWO LAYER ROOFFING MEMBRANE 2"X2" 6" ICF WALL ID. REV. DATE CHK BY APP GK REVISION DESCRIPTION date comm no. DRAWING NO. of PROJECT ADDRESS DRAWING TITLE DOB JOB No.: SHEET LIST: ISSUED FOR CONSTRUCTION 03.02.2025 15:23:44 BUILDING SECTIONS 15 4I & 4J Estate Joseph and Rosendahl St. Thomas, VI 00802 A-4 A-4 3/8" = 1'-0" A-4 1 BUILDING SECTION 1 3/8" = 1'-0" A-4 2 BUILDING SECTION 2 3/4" = 1'-0" A-4 4 PARAPET DETAIL 1 3/4" = 1'-0" A-4 5 PARAPET DETAIL 2 MOISTURE-RESISTANT DRYWALL STUD BLOCK BATHTUB SUBFLOOR JOIST DOUBLE TRIMMER 1. Floor/ceiling assembly: A. Flooring system: 1" thick plywood. B. Wood joist: Nom. 2" x 12" lumber joist. C. Ceiling system: 1 layer of 1/2" gypsum wallboard, per UL Design. 2. Metallic pipe: A. Steel pipe: 8" diameter (or smaller) schedule 40 (or heavier) steel pipe. B. Iron pipe: 8" diameter (or smaller) cast or ductile iron pipe. C. Conduit: 4" diameter (or smaller) electrical metallic tubing (EMT) or steel conduit. D. Copper tubing: 4" diameter (or smaller) Type L (or heavier) copper tubing. E. Copper pipe: 4" diameter (or smaller) regular (or heavier) copper pipe. Annular space from minimum 0" to maximum 7/8". 3. Forming and fire stop materials: A. Forming material (optional): Foam backer rod packed into opening as a permanent form. B. Type IA: Minimum 1/2" thick sealant applied within the annulus, flush with the top of the floor and bottom of the ceiling assemblies. Additional sealant to be applied such that a minimum 1/2" crown is formed around the penetrating item. FLOOR SHEATING LSSU (Z) HANGER @ STRINGER 2x12 STRINGER @ 16'' O.C. BEAM PER FRAMING PLAN FLOOR JOISRS AS PERFRAMING PLAN 2-2x6 TOP PLATE 2x6 STUD BEARING WALL 2-2x6 KING STUD MIN. PROVIDE 1 JACK STUDS MIN. EA. SIDE OF OPNG. OPEN 2-2x6 SOLE PLATE TREATED 2-2x6 KING STUD MIN. HEADER SEE SCHEDULE OR NOTES 2-2x6 SILL ID. REV. DATE CHK BY APP GK REVISION DESCRIPTION date comm no. DRAWING NO. of PROJECT ADDRESS DRAWING TITLE DOB JOB No.: SHEET LIST: ISSUED FOR CONSTRUCTION 03.02.2025 15:23:44 DETAILS 15 4I & 4J Estate Joseph and Rosendahl St. Thomas, VI 00802 A-5 A-5 NOT TO SCALE INSULATED WALL DETAILS NOT TO SCALE TYPICAL PLAN DETAILS NOT TO SCALE TOP PLATE FRAMING DETAIL NOT TO SCALE RAILING TYP. DETAIL NOT TO SCALE TYPICAL POST DETAIL NOT TO SCALE FLOOR PENETRATION DETAIL NOT TO SCALE TYPYCAL BEARING OF THE STEIRS 1" = 1'-0" FRAMING SUPPORTING BATHTUB 1" = 1'-0" WALL PENETRATION DETAIL 1/2" = 1'-0" TYPICAL WINDOW FRAMING