DOE EBO A2.0 SHT SEPT 14 2015
1. CONTRACTOR SHALL UPGRADE EXISTING ELECTRICAL AND PLUMBING SYSTEMS TO MEET CODE AND ADJUST AS NECESSARY TO ACCOMODATE NEW INSTALLATION OF NEW EQUIPMENT TO BE SUPPLIED BY DEPARTMENT OF EDUCATION. 2. ALL EXISTING FLOOR DRAINS TO BE SNAKED, CLEANED, AND WASHED OUT WITH WATER UNDER PRESSURE. 3. REMOVE EXISTING SINK AND FAUCET AND REPLACE WITH NEW STAINLESS STEEL SINK WITH NEW ADA FAUCET W/ AUTOMATIC HAND WASH SOAP DISPENSER ATTACHED TO WALL OVER NEW SINK 4.REMOVE EXISTING PLEXI GLASS PARTITION AND REPLACE W/ NEW SLIDING GLASS WINDOW 3'-0" w X 4'-0 h 5. REMOVE EXISTING COOLER FLOORING 12'-6" X 5'-0" AND REPLACE WITH NEW INSULATED COOLER FLOOR AS PER ACCEPTED STANDARDS FOR INSTALLATION OF WALK IN COOLER STORAGE. 6. ALL WALLS IN KITCHEN TO BE WASHED WITH HOT WATER AND DETERGENT TO SANATIZE AND REMOVE DIRT AND GREASE. THEN PREP WALL FOR REPAINTING WITH TWO (2) COATS OF EPOXY PAINT ( COLORS TO BE SPECIFIED BY ARCHITECT) 7. ALL DAMAGED AND DETERIORATED DRYWALL IN THE EXISTING CEILING OF THE KITCHEN AREA TO BE CUT OUT AND REPLACED WITH NEW WATER RESISTANT DRYWALL MATERIAL PATCH. …
Download the original document · Plain text (TXT) · Browse the archive · How this archive works
Original source: https://dpp.vi.gov/wp-content/uploads/2016/07/DOE_EBO-A2.0-SHT-SEPT-14-2015.pdf
SHA-256 9e6fdc2567a5b49c1c7dc668d65838cda31aebd2710c9e42dd711e295f340000
Re-using this document
A public record of the Government of the Virgin Islands, published by the agency itself. No copyright is asserted on it and 17 U.S.C. § 105 does not reach territorial government, so it publishes as a territorial public record.
Our description, tagging, arrangement, extracted text and machine transcripts are released under CC0 1.0. We assert nothing about the document itself.
Archive identifier LF-9e6fdc2567a5
Document text
1. CONTRACTOR SHALL UPGRADE EXISTING ELECTRICAL AND PLUMBING SYSTEMS TO MEET CODE AND ADJUST AS NECESSARY TO ACCOMODATE NEW INSTALLATION OF NEW EQUIPMENT TO BE SUPPLIED BY DEPARTMENT OF EDUCATION. 2. ALL EXISTING FLOOR DRAINS TO BE SNAKED, CLEANED, AND WASHED OUT WITH WATER UNDER PRESSURE. 3. REMOVE EXISTING SINK AND FAUCET AND REPLACE WITH NEW STAINLESS STEEL SINK WITH NEW ADA FAUCET W/ AUTOMATIC HAND WASH SOAP DISPENSER ATTACHED TO WALL OVER NEW SINK 4.REMOVE EXISTING PLEXI GLASS PARTITION AND REPLACE W/ NEW SLIDING GLASS WINDOW 3'-0" w X 4'-0 h 5. REMOVE EXISTING COOLER FLOORING 12'-6" X 5'-0" AND REPLACE WITH NEW INSULATED COOLER FLOOR AS PER ACCEPTED STANDARDS FOR INSTALLATION OF WALK IN COOLER STORAGE. 6. ALL WALLS IN KITCHEN TO BE WASHED WITH HOT WATER AND DETERGENT TO SANATIZE AND REMOVE DIRT AND GREASE. THEN PREP WALL FOR REPAINTING WITH TWO (2) COATS OF EPOXY PAINT ( COLORS TO BE SPECIFIED BY ARCHITECT) 7. ALL DAMAGED AND DETERIORATED DRYWALL IN THE EXISTING CEILING OF THE KITCHEN AREA TO BE CUT OUT AND REPLACED WITH NEW WATER RESISTANT DRYWALL MATERIAL PATCH. CONTRACTOR TO THEN PAINT CEILING WITH ONE COAT OF OFF WHITE EPOXY PAINT. 8.REMOVE EXISTING FIRE SUPRESSION SYSTEM FOR EXISTING EXHAUST HOOD AND REPLACE WITH NEW FIRE SUPRESSION SYSTEM AS APPROVED FROM CONTRACTOR SUBMISSION OR AS SPECIFIED BY ARCHITECT. REPAIR OR REPLACE DISPENSER NOZZLES TO FACILITATE PROPER OPERATION OF THE NEW SUPPRESSION SYSTEM. CONTRACTOR TO UPGRADE ALL ELECTRICAL AND OTHER EXISTING SYSTEMS THAT WILL BE REQUIRED TO FACILITATE PROPER OPERATION OF THE SYSTEM. 9. REMOVE EXISTING DETERIORATED WOOD LEDGE AND REPLACE WITH NEW MOISTURE RESISTANT HARD SURFACE LIKE CORIAN OR STAINLESS STEEL AT DISH RETURN COUNTER. 10. CONTRACTOR TO SUPPLY AND INSTALL NEW 12,000 BTU SPLIT UNIT AIR CONDITIONING UNIT WITH ELECTRICAL AS IS CONNECT AS PER ALL CODE REQUIREMENTS FOR OFFICE NO. 104 11. CONTRACTOR SHALL CONSTRUCT NEW REINFORCED BLOCKED ENCLOSURE WITH GATE FOR NEW PROPANE TANKS (53 SQ.FT) AS PER DETAILS ON DRAWINGS 12. CONTRACTOR SHALL NOT INSTALL OR CONSTRUCT ANY ITEMS IN EXISTING EXCAVATED AREA FOR INSTALLATION OF GREASE TRAPWILL BE PROVIDED BY OTHERS. 13. ALL EXISTING PLUMBING LINES TO BE CHECKED FOR BREAKS AND LEAKS AND SHALL BE UPGRADED TO CODE WHEREVER EXISTING IS NOT COMPLYING WITH CODE. 14.CONTRACTOR TO CHECK EXISTING DUCTWORK AND ESTABLISH AND VERIFY IF SYSTEM IS FULLY OPERABLE AND IN ACCORDANCE WITH REQUIRED NEC CODES FOR AIR CONDITIONING INSTALLATION AND OPERATION. CONTRACTOR SHALL CUT EXISTING CONCRETE SLAB 12" AS INDICATED THE DRAWING APPROXIMATELT 12" FT LONG TO ACCOMODATE THE INSTALLATION OF LINE FOR DRAIN FROM NEW KETTLE. AFTER INSTALLATION BY OTHERS ARE COMPLETED CONTRACTOR SHALL ENCLOSE CUT SLAB WITH CONCRETE AND REINSTALL TILES TO MATCH EXISTING CONTRACTOR SHALL ALSO CUT EXISTING CONCRETE SLAB 8" WIDE MINIUM APPROXIMATELY 18' FT LONG TO ACCOMODATE THE INSTALLATION OF BLACK IRON PIPE LOCATED IN PVC SLEEVE AND RECOVER CUT HOLE AFTER INSTALLATION WITH CONCRETE TILE TO MATCH EXISTING 15. CONTRACTOR SHALL REMOVE EXISTING WOODEN DOORS AND HARDWARE (LOCKSET AND HINGES) AND REPLACE WIHT NEW IMBUIA WOOD DOOR OR METAL DOOR WITH VIEW PANEL AS (NOTED ON DRAWING) WITH NEW LOCKSET HINGES TO MATCH OR UPGRADE ON EXISTING. 16. ELECTRICIAN SHALL VERIFY THAT ALL EXISTING PANELS/FLOOR/WALL MOUNTED RECEPTACLES ARE IN COMPLIANCE WITH NEC AND LOCAL BUILDING CODES. VERIFY ALL NEW EQUIPMENT ELECTRICAL REQUIREMENTS ALSO . ELECTRICIAN TO UPGRADED ELECTRICAL SYSTEM AS REQUIRED FOR INSTALLATION OF NEW FIXTURES AND EQUIPMENT. DISCONNECT AND CAP ALL ELECTRICAL ITEMS THAT WILL NOT BE USED BASED ON THE MANUFACTURER'S SPECIFICATIONS AND REQUIREMENTS OF THE NEW EQUIPMENT CONTRACTOR . VERIFYEXISTING EXHAUST HOOD AND FAN ARE OPERABLE AND IF THEY ARE NOT UP GRADE AS REQUIRED. 17. CONTRACTOR TO PAINT EPOXY ACCENT STRIP FROM CEILING 32" TO HEAD OF EXISTING DOOR HEIGHT COLOR TO BE ESTABLISHED BY ARCHITECT. ALL WALLS SHALL BE PRESSURED WASHED AND SANITIZED WITH HEALTH CODE COMPLIANT AGENTS. CONTRACTOR TO PREPARE WALLS AND CEILING TO RECEIVE NEW EPOXY PAINT TO MATCH EXISTING COLORS EXCEPT FOR NEW ACCENT BAND 18. CONTRACTOR TO CLEAN EXISTING QUARRY TILE WITH MURIATIC ACID SOLUTION AND THEN SEAL WITH HI-QUALITY TILE SEALER. SEALER TO BE SUBMITTED FOR APPROVAL. 19. REMOVE EXISTING DOOR AND HARDWARE AS NOTED ON DRAWING AND REPLACE WITH NEW HINGES HARDWARE AND DOOR AS SPECIFIED. CONTRACTOR SPRAY NEW DOORS TO MATCH EXSITING COLOR OF THE EXISTING DOORS 20. UPGRADE FIRE SUPRESSION SYSTEM AS SPECIFIED W/ NEW AMEREX CORP FIRE SUPPRESSION SYSTEM. AT THE EXISTING HOOD. VERIFY THAT NOZZLES INSTALLED AT EXISTING HOOD IS OPERABLE . IF NOT NOZZELS AT HOOD EXHAUST SYSTEM WILL NEED TO BE UPGRADED. MAKE SURE THE EXHAUST HOOD MEETS THE EQUIPMENT REQUIREMENTS OF THE KITCHEN AND IS INSTALLED AS PER EQUIPMENT MANUFACTURER SPECIFICATIONS. 21. REMOVE EXISTING FIRE SUPRESSION SYSTEM FOR EXHAUST HOOD. CONTRACTOR TO INSTALL NEW FIRE SUPRESSION SYSTEM SPECIFIED. AS PER MANUFACTURERS SPECIFICATIONS AND UPGRADE ALL EXISTING ANCILLARY ELEMENTS THAT ARE REQUIRED FOR THE EXHAUST HOOD AND THE NEW FIRE SUPRESSION SYSTEM OPERATE PROPERLY 22. EXISTING COOLER AND FREEZER DOOR SEALERS TO BE REMOVED AND INSTALL NEW RUBBER SEALERS AS REQUIRED AS PER MANUFACTURERS REQUIREMENTS. 23. CONTRACTOR TO INSPECT ALL LIGHTING FIXTURES IN CEILING AND EITHER REPLACE BALLASTS OR LIGHT BULBS FOR EXISTING FIXTURE AS REMOVE EXISTING HOSE BIB AND HANDLES AND REPLACE WITH ONE TO BE APPROVED BY ARCHITECT REQUIRED. 24. REMOVE EXISTING GATE AT LOADING DOCK AND REPLACE W/ NEW METAL GATE OF 1 5" X 1 4" SQUARE HOLLOW TUBING WITH LATCHSET FOR PADLOCK AND 3 HINGS. 25. RELOCATE AS DIRECETED BY DOE AND UPGRADE EXISTING ELECTRICAL PANEL THAT OPERATES THE HEAVY DUTY EXISTING MIXER. ENSURE THAT THE ELECTRICAL UPGRADE\IS TO CODE AND MEETS THE OPERATIN REQUIREMENTS FOR EXISTIN EQUIPMENT. 26. REMOVE 4'-0" HIGH LOWER PORTION OF EXISTING PARTITION WALL AS INDICATED ON BOTHSIDES. REPLACE NEW WIRE SHELVING NEW WIRE SHELVING NEW WIRE SI HELVING NEW WIRE BHELVING NEW WIRE SHELVING STORAGE [107 | NEW NEW WIRE SHELVING WIRE SHELVING NEW WIRE SHELVING - WIRE|SHELVIN WITH DURO ROCK OR EQUAL MOISTU BS) rT RESISTANT SHEATHING FOR THE LO SECTION OF THE WALL. CONTRACTO SHALL VERIFY QUANTITY +- 400 SQ FEET. DEPENDING ON CONDITIONS QE D/ | THE INTERIOR STUDS FRAME CONTRACTOR MIGHT HAVE TO ADD WOOD STUDS TO BRACE EXISTING FRAMING MEMBERS. CONTRACTOR | INSPECT AND NOFITY ARCHITECT OF FINDING BEFORE DOING ANY WORK. N CQOLER 6 WIRE SHELVING NEW WIRE SHELVING NEW FREEZER [106 | WIRE SHELVING NEW er WIRE SHELVING NEW JANITORS [106 | WIRE SHELVING 12-2 Kal I NEW WIRE SHELVING NEW YARE- SHEL NEW is S--=-- (2 A2V A2. 27.CONTRACTOR SHALL TERMITE TREAT KITCHEN AND STAGE AREA AND CAFETERIA AREA . TERMITE TREATMENT SHALL INCLUDE THE BORING OF HOLES INTO EXISTING DRYWALL PARTITIONS AND THEN APPLYING OF TERMITE TREATMENT AGENT INSIDE THE CAVITY OF THE WALLS. 28. CONTRACTOR TO CUT SLAB TO ACCOMODATE NEW GAS LINE AND COPPER LINE FOR STEAM KETTL PROVIDED BY OTHERS. CONTRACTOR SHALL REPAIR AND CLOSE SLAB AND RETILE W/ TILE TO MATCH AFTER ALL INSTALLATIONS ARE COMPLETED. 4 COMPARTMENT 64"X30" || EXISTING WARMING CABINET || NEW WARMING DCS4-CFUR FOR ELECTRICAL AND PLUMBING ROUGH IN SEE SPECIS PROVIDED BY DEPT OF EDUCATION 5 COMPARTMENT HOT WELLS 78"X30" DCS-5-HFU-8 SEE SPECS PROVIDED BY CABINET 25X30X71 NEW 8 BURNER STOVE 9 48"X34"X6" oN 3 COMPARTMENT SINK FFN2760-3-24-14/3 (SEE SPEC SHEETS FOR PLUM BING ROUGH IN PROVIDED BY DEPT. OF EDUCATION GAS \ GAS LINE DENOTES AREA THAT HAS BEEN EXCAVATED DOE CONTRACTOR TO CUT 12" MIN. EXISTING KITCHEN FLOOR SLAB VA [| L _ [crease | eae | "X2'-6"xX2'-0 Se SDS — OC TO ACCOMODATE DRAIN LINE SINK FN2448-2 FOR KETTLE INSTALLATION OF DRAIN LINE AND GREASE TRAP BY OTHERS |__ INSTALLATION OF DRAIN LINE AND GREASE LINE TO BE INSTALLED BY OTHERS 2 COMPARTMENT (SEE SPEC SHEETS FOR PLUMBING ROUGH | IN PROVIDED BY DEPT. OF EDUCATION a Ww NEW 5' HIGH CHAIN LINK FENCING SURROUNDING THE NEW PROPANE TANK ENCLOSURE ) O {\ [] 8X8 DECO BLOCK —— iy > ”a DBL DECK GAS CONVECTION OVEN PROPANE r— GAS GAs — i INEW BRAISING PAN VG40 DEPT OF EDUCATION FOR ELECTRICAL AND PLUMBING ROUGH INS. un JUUUU UO EXISTING SOFT SERVE ICE CREAM im EXISTING CART EXISTING CART i —| MAIN KITCHEN GAS EXISTING | TABLE | GAS GAS GA NEW TABLE 108"X30" | EXISTING | MIXER ta/2p i7- 26 fa- = NEW DW NEW TABLE ! 60" X 30" | ——_—|] 1818-1-1614 " SINGLE COMPARTMENT SINK osusuen[Q] MODEL NO. AM15 Kes CONTRACTOR TO cut " EXISTING KITCHEN S TO ACCOMODATE GAI LINE FOR NEW KITCH EQUIPMENT AS PER MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH LOCAL CODES. NEW S.STEEL DISH TABLE DTC-S30-60-LOR R NEW COUNTER AT TRAY RETURN T BE MOSITURE RESISTA AND SOLID SURFAC NOT BACTERIA FOR MATERIAL GAS GAS TANK a ee 5-0 <RSS. —O YW o \ N 8X8 DECO BLOCK _/ UY UY EXISTING CHAIN LINK = / FENCE (2)- 125 GALLON TANKS CONNECTED WITH FITTINGS 8 AB oe NEPA AND | | | | | | | | | 4 fa 5 | PROPOSED EQUIPMENT LAYOUT & NOTES SCALE 1/4"= 1'-0" JOINED TOTALING 250 GALLONS PROPANE . CONTRACTOR TO INSTALL SCHEDULE 80 IRON LINE AS PER NFPA 58 AND LOCAL BUILDING CODE INTERIOR GAS LINE SIZED AS PER NFPA 58 CODE LINE TO BE INSTALLED BURIED IN PVC SLEEVE. EXTERIOR LINE TO HAVE SIGNAGE REQUIRED BY CODE TO IDENTIFY GAS LINE (1 88 LOCATION@ EXTERIOR OF BUILDING SYMBOLS LEGEND NQBo 5 DENOTES PROPOSED WORK NOTATIONS DOOR MARK/NOTATION ROOM NUMBER DESIGNATION WINDOW MARK/NOTATION DENOTES LOWER PORTION OF WALL SHEATHING TO BE REMOVED AND INSTALL CEMENT BOARD AT BOTHSIDES OF EXISTING WALL PARTITION LL] DENOTES EXISTING WALL EXTERIOR AND INTERIOR WALLS LPe . , & Caribbean . DProfessional q Consultants 2 a roe 4 fv 212 BOURNEFIELD LINDBERG BAY, S OMAS P.O.Box 305647 St.Thomas U.S.V.I. 00803 Tel.: 340-774-3357 YO! & = eS) Y S Li] O- Es S 5 — x | 8 an: 5 1a = | & oa |< =) Zz g |@ 4 = wo Zz LW O LU jIcZz S| eee EO) Gok SE sro ep) i Z a ZO “an QOz| Sic WW < tos Ke) 6 Za2 Og) URE faa) OE OS 5 aa Lu -— Y) DRAWN BY LD CHECKED BY: E. BLAIZE APPROVED BY: E. BLAIZE CONTRACT NO.: CONTRACT.NO. PROJECT NO.: PROJ.NO. DATE: i000», CRED ALCP Sy s "Ra, Os 2. ses, Vs 4 OS ees y \<8 3, aN NoSS1 OS. $ 6 Lye caer, < ‘ i Git Yor *20azap900008° 1 BCALE 1/4"= 1'-Of -PROPOSED NOTES PROPOSED EQUIPMENT LAYOUT AND NOTES SHEET NO.: A 2.0 SHEET NO. # OF # SHEETS