VI Update

USVI Public Records

A VI Update Project · Brian LoudenThe territory’s public record — kept public.

2025-11-21 – Knud Hansen DOH OMH Demolition Set

Collection
Research & Technical Reports
Sub-shelf
dpnr.vi.gov
Kind
Research Report
Date
2025-11-21
Topics
Disaster Recovery
Pages
20
Text
Native Text

OWNER ARCHITECT Government of the United States, Virgin Islands HONORABLE ALBERT BRYAN, JR. GOVERNOR HONORABLE TREGENZA A. ROACH, ESQ LIEUTENANT GOVERNOR Government House St. Thomas 5047 (21-22) Kongens Gade, St. Thomas, VI 00802-6487 PHONE: (340) 774-0001 EMAIL: albert.bryan@go.vi.gov Office of Disaster Recovery Adrienne L. Williams-Octalien DIRECTOR V.I Public Finance Authority Office of Disaster Recovery 14A & 14C Strand Street Frederiksted, VI 00840 PHONE: (340) 202-1221 EMAIL: adrienne.williams@vi.gov Springline Architects, LLC Jerry Traino, AIA PRINCIPAL Gilbert Laban, RA PRINCIPAL 9713 Estate Thomas Building 1, Suite 200 St. …

Download the original document · Plain text (TXT) · Browse the archive · How this archive works

Original source: https://dpnr.vi.gov/wp-content/uploads/2026/06/2025-11-21-Knud-Hansen-DOH-OMH-Demolition-Set.pdf

SHA-256 b9785f696d6facb685102d29e2be70a1637f9528479825df6422a20af0a52e2f

Re-using this document

A public record of the Government of the Virgin Islands, published by the agency itself. No copyright is asserted on it and 17 U.S.C. § 105 does not reach territorial government, so it publishes as a territorial public record.

Our description, tagging, arrangement, extracted text and machine transcripts are released under CC0 1.0. We assert nothing about the document itself.

Archive identifier LF-b9785f696d6f

Document text

OWNER ARCHITECT Government of the United States, Virgin Islands HONORABLE ALBERT BRYAN, JR. GOVERNOR HONORABLE TREGENZA A. ROACH, ESQ LIEUTENANT GOVERNOR Government House St. Thomas 5047 (21-22) Kongens Gade, St. Thomas, VI 00802-6487 PHONE: (340) 774-0001 EMAIL: albert.bryan@go.vi.gov Office of Disaster Recovery Adrienne L. Williams-Octalien DIRECTOR V.I Public Finance Authority Office of Disaster Recovery 14A & 14C Strand Street Frederiksted, VI 00840 PHONE: (340) 202-1221 EMAIL: adrienne.williams@vi.gov Springline Architects, LLC Jerry Traino, AIA PRINCIPAL Gilbert Laban, RA PRINCIPAL 9713 Estate Thomas Building 1, Suite 200 St. Thomas, USVI 00802 PHONE: (321) 636-0274 EMAIL: gilbert@springlinearchitects.com jerry.traino@novusarchitects.com STRUCTURAL ENGINEER CIVIL ENGINEER Harris Civil Engineers, LLC Neil Wolfe, PE PROJECT MANAGER 1200 Hillcrest Street, Suite 200 Orlando, FL 32803 PHONE: (407) 629-4777 EMAIL: NeilW@harriscivilengineers.com SURVEYOR TLC Engineering Solutions Joel Figueroa-Vallines, PE SENIOR ASSOCIATE 7370 Cabot Court, Suite 103 Melbourne, FL 32940 PHONE: (321) 877-4231 EMAIL: joel.figueroa@tlc-eng.com The Green Piece Engineering + Environment Jeffrey Bateman, PE, PLS PRINCIPAL 5001 Chandlers Wharf, Suite 12 Christiansted, St. Croix, VI 00820 PHONE: (340) 778-7474 EMAIL: jeff@thegreenpiece.us Department of Public Works Derek Gabriel COMMISSIONER Jermaine McCleane, RA DISTRICT ENGINEERING 8244 Subbase St. Thomas, VI 00802 PHONE: (340) 776-4844 EMAIL: jermaine.mccleane@dpw.vi.gov Department of Health Justa E. Encarnacion COMMISSIONER Reuben Molloy ASSISTANT COMMISSIONER 4006 Estate Diamond Christiansted, St. Croix, VI 00820 PHONE: (340) 774-0001 EMAIL: reuben.molloy@doh.vi.gov Jacobs Christopher Cangello SENIOR PROJECT MANAGER S Warren Street Syracuse, NY PHONE: (315) 209-9713 EMAIL: christopher.cangello@jacobs.com ATLANTIC OCEAN CARIBBEAN SEA THE ISLAND OF ST. THOMAS PROJECT LOCATION SITE REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Programming B 60% CDs C 90% CDs D 100% CDs E 30% CDs PROJECT TEAM PROJECT MAP AGENCIES ODR TASK ORDER NUMBER SHEET INDEX ODR TASK ORDER #: G000 11/21/2025 KB RCC 1303 Hospital Ground, Knud Hansen Complex St. Thomas, US. Virgin Islands 00802 OLD MENTAL HEALTH BUILDING DEMOLITION AND PARKING LOT COVER SHEET 60% DEMOLITION DRAWINGS 470-21-34 60% DEMOLITION DRAWINGS 1303 Hospital Ground, Knud Hansen Complex St. Thomas, US. Virgin Islands 00802 OLD MENTAL HEALTH BUILDING DEMOLITION AND PARKING LOT 2020-03 2020-03 10.15.25 CR # SHEET # SHEET NAME GENERAL G000 COVER SHEET G004 ABBREVIATIONS, LEGENDS, KEYNOTES G005 DEMOLITION REFERENCE PHOTOS G006 DEMOLITION REFERENCE PHOTOS G007 DEMOLITION REFERENCE PHOTOS CIVIL C0.00 COVER SHEET C0.01 GENERAL NOTES C0.90 DEMOLITION AND EROSION CONTROL PLAN C1.00 SITE PLAN C2.00 GRADING PLAN C2.50 DRAINAGE PLAN C3.00 UTILITY PLAN C4.00 DETAILS C4.01 DETAILS C4.02 DETAILS C4.03 DETAILS ARCHITECTURAL D001 DEMOLITION SITE PLAN D101 DEMOLITION FLOOR PLANS D201 DEMOLITION ELEVATIONS & SECTION No. Description Date X X X REFERENCE SYMBOL LEGEND ROOM NAME AND NUMBER PLAN OR SECTION DETAIL DASHED LINE AROUND AREA DETAILED DRAWING NUMBER SHEET NUMBER WHERE DETAIL IS DRAWN BUILDING, WALL, OR CASEWORK SECTION DRAWING NUMBER SHEET NUMBER WHERE SECTION IS DRAWN INTERIOR ELEVATION DRAWING NUMBER SHEET NUMBER WHERE ELEVATION IS DRAWN LOBBY 100 A1 A101 100 SF ROOM NAME ROOM NUMBER ROOM AREA EXTERIOR ELEVATION DRAWING NUMBER SHEET NUMBER WHERE ELEVATION IS DRAWN DOOR TAG ROOM WHERE DOOR IS LOCATED DOOR ID - REFER TO DOOR SCHEDULE STOREFRONT TAG DRAWING NUMBER SEE A600 SERIES FOR STOREFRONT ELEVATIONS WALL OR PARTITION TAG A1 REFER TO A001 FOR PARTITION DETAILS WINDOW TAG A1 REFER TO A601 FOR WINDOW ELEVATIONS 101A 1 ABBREVIATIONS AB AIR BARRIER AB ANCHOR BOLT ABV ABOVE ACT ACOUSTICAL CEILING TILE ADD ADDITIONAL, ADDENDUM ADJ ADJUSTABLE, ADJACENT AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AHJ AUTHORITY HAVING JURISDICTION AHU AIR HANDLING UNIT ALT ALTERNATE, ALTERNATIVE ALUM ALUMINUM ANOD ANODIZED ARCH ARCHITECTURAL, ARCHITECT ATS AUTOMATIC TRANSFER SWITCH AVG AVERAGE B&S BACKER ROD AND SEALANT BAC BUILDING AUTOMATION AND CONTROLS BATTS BATT INSULATION BC BACK OF CURB BD BOARD BIT BITUMINOUS BLDG BUILDING BLKG BLOCKING BM BEAM BOD BASIS OF DESIGN BOS BOTTOM OF STEEL BOT BOTTOM BRG BEARING BRK BRICK BUR BUILT-UP ROOFING C/C CENTER TO CENTER CAB CABINET CC CONTRACTOR PROVIDED / CONTRACTOR INSTALLED CIP CAST IN PLACE CONCRETE CJ CONTROL JOINT CL CENTERLINE CLG CEILING CLKG CAULKING CLO CLOSET CLR CLEAR CMU CONCRETE MASONRY UNIT CO CLEANOUT, CASED OPENING COL COLUMN CONC CONCRETE CONST CONSTRUCTION CONT CONTINUOUS, CONTROL CTR CENTER CW COLD WATER D DEPTH DBL DOUBLE DEMO DEMOLISH, DEMOLITION DET DETAIL DF DRINKING FOUNTAIN DHW DOMESTIC HOT WATER DIA DIAMETER DIM DIMENSION DIV DIVISION, DIVIDE DN DOWN DOAS DEDICATED OUTDOOR AIR SYSTEM DP DRAIN PIPE, DAMPPROOF DS DOWNSPOUT DWG DRAWING DWR DRAWER EA EACH EF EACH FACE EF EXHAUST FAN EFS EXTERIOR FINISH SYSTEM EIFS EXTERIOR INSULATION AND FINISH SYSTEM EJ EXPANSION JOINT EL EACH LAYER ELEC ELECTRIC SPACE, ELECTRICAL ELEV ELEVATOR, ELEVATION EMER EMERGENCY ENCL ENCLOSURE ENG ENGINEER, ENGINEERED EP ELECTRICAL PANEL EPS EXPANDED POLYSTYRENE INSULATION EQ EQUAL EQUIP EQUIPMENT ES EACH SIDE ETR EXISTING TO REMAIN EW EACH WAY EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER EXCAV EXCAVATE EXH EXHAUST EXIST EXISTING EXP EXPANSION, EXPOSED EXT EXTERIOR FA FIRE ALARM FAAP FIRE ALARM ANNUCIATOR PANEL FAB FABRICATE FACP FIRE ALARM CONTROL PANEL FC FIBER CEMENT FD FLOOR DRAIN FDC FIRE DEPARTMENT CONNECTION FDTN FOUNDATION FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FF FINISHED FLOOR, FACTORY FINISH FF&E FIXTURES, FURNISHINGS, & EQUIPMENT FFE FINISHED FLOOR ELEVATION FIN FINISH, FINISHED FLR FLOOR FM FIRE MARSHAL FO FINISHED OPENING FOC FACE OF CONCRETE FOF FACE OF FINISH FOM FACE OF MASONRY FOS FACE OF STUD FRT FIRE RETARDANT TREATED FS FLOOR SINK FSTN FASTEN, FASTENER FT FEET FTG FOOTING FV FIELD VERIFY (SEE ALSO: VIF) GALV GALVANIZED GB GRAB BAR GC GENERAL CONTRACTOR GEN GENERATOR GFCI GROUND FAULT CIRCUIT INTERRUPTED GFI GROUND FAULT INTERRUPTED GL GLAZING GND GROUND GOVT GOVERNMENT GR GUARD RAIL GRD GRADE GRTG GRATING GT GROUT GVL GRAVEL GWB GYPSUM WALL BOARD GYP GYPSUM H HIGH HAZMAT HAZARDOUS MATERIAL HB HOSE BIB HC HANDICAPPED ACCESSIBLE HCWD HOLLOW CORE WOOD HDR HEADER HM HOLLOW METAL HORIZ HORIZONTAL HR HANDRAIL HSS HOLLOW STRUCTURAL SECTION HT HEIGHT HVAC HEATING VENTILATION AIR CONDITIONING HW HARDWARE HWS HOT WATER SUPPLY ID INTERIOR DIAMETER IGU INSULATED GLASS UNIT INS INSULATION INSUL INSULATION INT INTERIOR, INTERNAL IR IMPACT RESISTANT JBOX JUNCTION BOX JF JOINT FILLER JS JOINT SEALANT JST JOIST JT JOINT KD KNOCK-DOWN, KILN-DRIED L LENGTH, LEFT LAV LAVATORY LH LEFT HAND LNDG LANDING LNTL LINTEL LOD LIMITS OF DISTURBANCE LP LIGHTING PANEL LSL LAMINATED STRAND LUMBER LTG LIGHTING LVL LEVEL, LAMINATED VENEER LUMBER LVR LOUVER MATL MATERIAL MAX MAXIMUM MDF MEDIUM DENSITY FIBERBOARD MECH MECHANICAL MED MEDIUM MEMB MEMBRANE MEZZ MEZZANINE MFR MANUFACTURE, MANUFACTURER MH MANHOLE MIN MINIMUM MIR MIRROR MISC MISCELLANEOUS MO MASONRY OPENING MOV MOVABLE MR MOISTURE RESISTANT MS MOP SINK MTD MOUNTED MTL METAL MUA MAKE UP AIR NIC NOT IN CONTRACT NIS NOT IN SCOPE NO NUMBER NOM NOMINAL NRC NOISE REDUCTION COEFFICIENT NTS NOT TO SCALE OA OVERALL, OUTSIDE AIR OC ON CENTER OD OUTSIDE DIAMETER OF OUTSIDE FACE OH OVERHEAD OP OPERABLE OPNG OPENING OPP OPPOSITE, OPPOSITE HAND ORD OVERFLOW ROOF DRAIN OSB ORIENTED STRAND BOARD PAF POWDER ACTUATED FASTENER PEMB METAL BUILDING MANUFACTURER PL PLASTIC LAMINATE PLBG PLUMBING PLTF PLATFORM PLYWD PLYWOOD PME PLUMBING, MECHANICAL, AND ELECTRICAL PNL PANEL POTW POTABLE WATER PR PAIR PREFAB PREFABRICATED PREFIN PREFINISHED PROP PROPERTY LINE PSL PARALLEL STRAND LUMBER PT PAINT PT PRESSURE TREATED PTD PAINTED PTN PARTITION PVC POLYVINYL CHLORIDE QTR QUARTER QTY QUANTITY R RISER, RIGHT R/I ROUGH-IN RA RETURN AIR RAD RADIUS RCP REFLECTED CEILING PLAN RD ROOF DRAIN RDL ROOF DRAIN LEADER REBAR REINFORCING STEEL BAR RECP RECEPTACLE REF REFERENCE REFURB REFURBISH REINF REINFORCE REINFORCING REINFORCEMENT REM REMOVE, REMOVABLE REQD REQUIRED RET RETAINING, RETURN REV REVERSE, REVISION RFG ROOFING RGH ROUGH RIG RIGID RM ROOM RND ROUND RO ROUGH OPENING ROW RIGHT OF WAY RS ROUGH SAWN RTD RATED SA SELF-ADHERED, SUPPLY AIR SAN SANITARY SB SPLASH BLOCK SBS STYRENE-BUTADIENE-STYRENE INSULATION SCH, SCHED SCHEDULE SCR SCREEN SCUP SCUPPER SCWD SOLID CORE WOOD SECT SECTION SF SQUARE FOOT / SQUARE FEET SFGL SAFETY GLASS SHT SHEET SHTG SHEATHING SHWR SHOWER SIM SIMILAR SIP STRUCTURAL INSULATED PANEL SK SINK SLC SELF-LEVELING COMPOUND SM SHEET METAL SNT SEALANT SOG SLAB ON GRADE SP STAND PIPE, SOUNDPROOF SPEC SPECIFICATION, SPECIFIED SPRNK SPRINKLER SQ SQUARE SS STAINLESS STEEL STANDING SEAM SOLID SURFACE SSK SERVICE SINK STC SOUND TRANSMISSION CLASS STD STANDARD STL STEEL STN STATION STR STAIR STRUCT STRUCTURAL SUSP SUSPEND, SUSPENDED SW STORM WATER, SHEAR WALL SYP SOUTHERN YELLOW PINE T TREAD T&B TOP AND BOTTOM T&G TONGUE AND GROOVE TD TRENCH DRAIN TEMP TEMPERATURE, TEMPORARY TGL TEMPERED GLASS THK THICK TLT TOILET TME TO MATCH EXISTING TOC TOP OF CURB TOS TOP OF SLAB, TOP OF STEEL TOW TOP OF WALL TP TOP OF PAVEMENT TPTN TOILET PARTITION TRANS TRANSFORMER TRTD TREATED TSTAT THERMOSTAT TWF THRU WALL FLASHING TYP TYPICAL UNFIN UNFINISHED UNO UNLESS NOTED OTHERWISE UR URINAL VAV VARIABLE AIR VOLUME VB VAPOR BARRIER VERT VERTICAL VIF VERIFY IN FIELD (SEE ALSO: FV) VP VENT PIPE VR VAPOR RETARDER VRF VARIABLE REFRIGERANT FLOW VTR VENT THROUGH ROOF W WIDE, WIDTH W/ WITH W/O WITHOUT WC WATER CLOSET WD WOOD WG WIRE GLASS WH WATER HEATER, WALL HYDRANT WIN WINDOW WS WEATHER STRIPPING WWM WELDED WIRE MESH (FABRIC) XPS EXTRUDED POLYSTYRENE INSULATION EXISTING WALL TO REMAIN DEMOLITION SYMBOL LEGEND EXISTING WALL TO BE DEMOLISHED EXISTING DOOR TO BE DEMOLISHED NOT IN SCOPE / TO REMAIN DOH OLD MENTAL HEALTH BUILDING SCOPE DOH KNUD HANSEN TOWER SCOPE (FUTURE PHASE - SCOPE NOT NOTED IN THIS DRAWING SET) DHS KNUD HANSEN BUILDING SCOPE (FUTURE PHASE - SCOPE NOT NOTED IN THIS DRAWING SET) TEMPORARY CONSTRUCTION FENCING 4" 1' - 4" 2' - 0" 4' - 0" 8' - 0" PT 1/2" PLYWOOD FRONT AND BACK PT 4X POST PT 2X4 FRAMING BETWEEN POSTS SONOTUBE FOOTING NOTE TO CONTRACTOR: 1. SIGN GRAPHICS TO BE PROVIDED BY ODR 2. VERIFY LOCATION OF SIGN ONSITE WITH ODR PROJECT MANAGER 3 ROW BARBED WIRE TO MATCH EXISTING - INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS 1 5/8" O.D. TOP RAIL TOP RAIL WIRES AT 24" O.C. 1. 2. 3. NOTE: All posts shall be installed vertically. Where posts are installed on an inclined surface, the angle of the post shall be adjusted so that the post will be vertical. All fencing shall be 2" Mesh, 9 Gauge Galvanized wire. All posts shall be Galvanized, Schedule 40 Steel pipe. 4" O.D. TERMINAL POST POST TIE WIRES AT 15" O.C. 1-5/8" O.D. BOTTOM RAIL HOOK BOLT (TYP.) STRETCHER BAR 4500 PSI CONCRETE VERIFY 8' - 0" 4" MAX. TYP. 6" 4' - 0" TYP. TYP. 1' - 0" 2 7/8" O.D. LINE POST AT 8' - 0" O.C. REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Programming B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR TASK ORDER NUMBER G004 11/21/2025 KB RCC 1303 Hospital Ground, Knud Hansen Complex St. Thomas, US. Virgin Islands 00802 OLD MENTAL HEALTH BUILDING DEMOLITION AND PARKING LOT ABBREVIATIONS, LEGENDS, KEYNOTES 60% DEMOLITION DRAWINGS 470-21-34 2020-03 10.15.25 # KEYNOTES - OVERALL DEMOLITION # DESCRIPTION 01 DEMOLISH EXISTING BUILDING TO PROVIDED EXTENTS INCLUDING ROOF STRUCTURE, EXTERIOR AND INTERIOR WALLS, WINDOWS, DOORS, FLOORS AND FLOOR SLABS, ALL BUILDING UTILITIES: PIPING, DUCTWORK, ELECTRICAL, FIXTURES AND DEBRIS DOWN TO SOIL (TYPICAL) 02 DEMOLISH EXISTING SIDEWALKS, STAIRS, RAMPS, AND RAILINGS TO GRADE 03 DEMOLISH EXISTING RETAINING WALL; CONTRACTOR IS RESPONSIBLE FOR TEMPORARY SHORING OR STABILIZATION OF GRADE UNTIL PERMANENT CONSTRUCTION HAS BEEN PLACED. 04 DEMOLISH EXISTING ASPHALT PAVEMENT AS INDICATED ON CIVIL PLANS 05 MAINTAIN EXISTING GENERATOR AND ENCLOSURE DURING PHASE 1 06 DEMOLISH EXISTING CISTERN; FILL WITH CLEAN DIRT AS INDICATED ON CIVIL PLANS 07 RELOCATE EXISTING PLAYGROUND EQUIPMENT - CONTRACTOR TO COORDINATE WITH OWNER 08 DEMOLISH EXISTING VEGETATION AND TREES AS SHOWN 09 DEMOLISH EXISTING METAL STAIR STRUCTURE TO GRADE 10 DEMOLISH EXISTING AIR UNIT AND CONCRETE SLAB TO GRADE 11 MAINTAIN AND PROTECT EXISTING TREE 12 HISTORIC WALL TO REMAIN; CONTRACTOR IS REQUIRED TO STABILIZE AND PROTECT ALL PORTIONS TO REMAIN 13 HISTORIC STRUCTURE TO REMAIN; CONTRACTOR IS RESPONSIBLE FOR STABILIZATION AND PROTECTION OF ALL ELEMENTS DURING DEMOLITION. 14 MAINTAIN EXISTING STRUCTURE; CONTRACTOR IS RESPONSIBLE FOR STABILIZATION AND PROTECTION OF STRUCTURE DURING DEMOLITION 15 MAINTAIN EXISTING RETAINING WALL 16 DEMOLISH ALL EXISTING PERIMETER FENCING AND GATES AS INDICATED; REFER TO CIVIL 17 DEMOLISH EXISTING UTILITY POLE; REFER TO CIVIL 18 DEMOLISH EXISTING RAILING AT BALCONY 20 SECURE SITE PRIOR TO ANY DEMOLITION ACTIVITIES WITH 8' TALL CHAIN LINK FENCING WITH INTEGRATED WIND AND VISUAL BARRIER. 21 PROVIDE NEW ENTRY DRIVEWAY CUT 22 WHERE DHS BUILDING & HISTORIC BUILDING ABUT OLD MENTAL HEALTH BUILDING DEMOLITION SCOPE, CONTRACTOR TO USE SELECTIVE DEMOLITION, DELEGATED STRUCTURAL ENGINEERING, AND OTHER MEANS AND METHODS TO ENSURE DEMOLITION OF OLD MENTAL HEALTH BUILDLING DOES NOT COMPROMISE THE STRUCTURAL INTEGRITY OF THE DHS BUILDING AND HISTORIC STRUCTURE TO REMAIN. 3/4" = 1'-0" G004 ODR PROJECT SIGN 1 3/8" = 1'-0" G004 PERIMETER FENCING 3 No. Description Date X X X GENERAL DEMOLITION NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. THIS PLAN IS A GENERAL REPRESENTATION OF EXISTING CONDITIONS. IT IS INTENDED FOR REFERENCE ONLY. THIS PLAN IS NOT INTENDED TO BE A DETAILED DESCRIPTION OF ALL REQUIRED WORK. PRIOR TO CONSTRUCTION, CONTRACTOR TO FIELD VERIFY ALL SITE AND BUILDING LAYOUT DIMENSIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCY IMMEDIATELY. DIMENSIONS HAVE NOT BEEN FULLY VERIFIED AND ARE SHOWN FOR GENERAL DEFINITION OF SCALE AND EXTENTS OF SCOPE WHERE SHOWN. ALL TREES ARE TO REMAIN AND WHERE ADJACENT TO BUILDING DEMOLITION, SHOULD BE PROTECTED FROM ALL DAMAGE, TYPICAL, UNLESS OTHERWISE NOTED - REFER TO CIVIL. REMOVAL OF BUILDINGS SHALL INCLUDE ENTIRE SITE BEING CLEARED DOWN TO SOIL, TYPICAL. DEMOLITION INCLUDES HAULING AND PROPER DISPOSAL - REFER TO SPECIFICATIONS. DEMOLITION INCLUDES REMOVAL OF ALL TRASH AND ABANDONED VEHICLES ON SITE COORDINATE REQUIREMENTS AND LOCATION OF THE DEMARCATION WITH THE LOCAL TELEPHONE COMPANY AND IT DEPARTMENT. ALL AREAS NOT NOTED FOR DEMOLITION ARE TO BE PROTECTED. MAINTAIN TEMPORARY POWER TO SITE - COORDINATE WITH OWNER AND UTILITY. REFER TO CIVIL UTILITY LOCATIONS AND SITE DEMOLITION SCOPE. CONTRACTOR TO FIELD LOCATE EXISTING BUILDING POTABLE WATER AND SANITARY SEWER UTILITIES AND CAP SERVICES. CONTRACTOR TO COORDINATE UTILITY DEMOLITION WITH THE ST. THOMAS WATER AND POWER AUTHORITY (WAPA) AND WASTE MANAGEMENT AUTHORITY (WMA) PRIOR TO CONSTRUCTION. CONTRACTOR TO USE CAUTION WHEN DEMOLISHING SEWER PIPE KNOWN TO RUN BELOW BUILDING FOUNDATION. USE ALTERNATE MEANS SUCH AS BY-PASS PUMPING IF NECESSARY TO ENSURE CONTINUATION OF FLOWS DURING CONSTRUCTION. REPAIR PIPE IMMEDIATELY IF IMPACTED DURING FIELD WORK. CONTRACTOR TO REFER TO CIVIL ENGINEER FOR REMOVAL AND REPLACEMENT OF EXISTING ELECTRICAL INFRASTRUCTURE WITHIN THE BUILDING PRIOR TO DEMOLITION. REFER TO SHEETS G005-G007 FOR PICTURES OF EXISTING CONDITIONS. EXISTING WALL TO REMAIN DEMOLITION SYMBOL LEGEND EXISTING WALL TO BE DEMOLISHED EXISTING DOOR TO BE DEMOLISHED NOT IN SCOPE / TO REMAIN DOH OLD MENTAL HEALTH BUILDING SCOPE DOH KNUD HANSEN TOWER SCOPE (FUTURE PHASE - SCOPE NOT NOTED IN THIS DRAWING SET) DHS KNUD HANSEN BUILDING SCOPE (FUTURE PHASE - SCOPE NOT NOTED IN THIS DRAWING SET) TEMPORARY CONSTRUCTION FENCING KEYPLAN REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Programming B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR TASK ORDER NUMBER G005 11/21/2025 JT TKB 1303 Hospital Ground, Knud Hansen Complex St. Thomas, US. Virgin Islands 00802 OLD MENTAL HEALTH BUILDING DEMOLITION AND PARKING LOT DEMOLITION REFERENCE PHOTOS 60% DEMOLITION DRAWINGS 470-21-34 2020-03 10.15.25 5 4 5 3 1 2 6 4 3 1 2 6 No. Description Date X X X GENERAL DEMOLITION NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. THIS PLAN IS A GENERAL REPRESENTATION OF EXISTING CONDITIONS. IT IS INTENDED FOR REFERENCE ONLY. THIS PLAN IS NOT INTENDED TO BE A DETAILED DESCRIPTION OF ALL REQUIRED WORK. PRIOR TO CONSTRUCTION, CONTRACTOR TO FIELD VERIFY ALL SITE AND BUILDING LAYOUT DIMENSIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCY IMMEDIATELY. DIMENSIONS HAVE NOT BEEN FULLY VERIFIED AND ARE SHOWN FOR GENERAL DEFINITION OF SCALE AND EXTENTS OF SCOPE WHERE SHOWN. ALL TREES ARE TO REMAIN AND WHERE ADJACENT TO BUILDING DEMOLITION, SHOULD BE PROTECTED FROM ALL DAMAGE, TYPICAL, UNLESS OTHERWISE NOTED - REFER TO CIVIL. REMOVAL OF BUILDINGS SHALL INCLUDE ENTIRE SITE BEING CLEARED DOWN TO SOIL, TYPICAL. DEMOLITION INCLUDES HAULING AND PROPER DISPOSAL - REFER TO SPECIFICATIONS. DEMOLITION INCLUDES REMOVAL OF ALL TRASH AND ABANDONED VEHICLES ON SITE COORDINATE REQUIREMENTS AND LOCATION OF THE DEMARCATION WITH THE LOCAL TELEPHONE COMPANY AND IT DEPARTMENT. ALL AREAS NOT NOTED FOR DEMOLITION ARE TO BE PROTECTED. MAINTAIN TEMPORARY POWER TO SITE - COORDINATE WITH OWNER AND UTILITY. REFER TO CIVIL UTILITY LOCATIONS AND SITE DEMOLITION SCOPE. CONTRACTOR TO FIELD LOCATE EXISTING BUILDING POTABLE WATER AND SANITARY SEWER UTILITIES AND CAP SERVICES. CONTRACTOR TO COORDINATE UTILITY DEMOLITION WITH THE ST. THOMAS WATER AND POWER AUTHORITY (WAPA) AND WASTE MANAGEMENT AUTHORITY (WMA) PRIOR TO CONSTRUCTION. CONTRACTOR TO USE CAUTION WHEN DEMOLISHING SEWER PIPE KNOWN TO RUN BELOW BUILDING FOUNDATION. USE ALTERNATE MEANS SUCH AS BY-PASS PUMPING IF NECESSARY TO ENSURE CONTINUATION OF FLOWS DURING CONSTRUCTION. REPAIR PIPE IMMEDIATELY IF IMPACTED DURING FIELD WORK. CONTRACTOR TO REFER TO CIVIL ENGINEER FOR REMOVAL AND REPLACEMENT OF EXISTING ELECTRICAL INFRASTRUCTURE WITHIN THE BUILDING PRIOR TO DEMOLITION. REFER TO SHEETS G005-G007 FOR PICTURES OF EXISTING CONDITIONS. EXISTING WALL TO REMAIN DEMOLITION SYMBOL LEGEND EXISTING WALL TO BE DEMOLISHED EXISTING DOOR TO BE DEMOLISHED NOT IN SCOPE / TO REMAIN DOH OLD MENTAL HEALTH BUILDING SCOPE DOH KNUD HANSEN TOWER SCOPE (FUTURE PHASE - SCOPE NOT NOTED IN THIS DRAWING SET) DHS KNUD HANSEN BUILDING SCOPE (FUTURE PHASE - SCOPE NOT NOTED IN THIS DRAWING SET) TEMPORARY CONSTRUCTION FENCING KEYPLAN REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Programming B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR TASK ORDER NUMBER G006 11/21/2025 JT TKB 1303 Hospital Ground, Knud Hansen Complex St. Thomas, US. Virgin Islands 00802 OLD MENTAL HEALTH BUILDING DEMOLITION AND PARKING LOT DEMOLITION REFERENCE PHOTOS 60% DEMOLITION DRAWINGS 470-21-34 2020-03 10.15.25 3 4 3 1 2 1 2 4 No. Description Date X X X GENERAL DEMOLITION NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. THIS PLAN IS A GENERAL REPRESENTATION OF EXISTING CONDITIONS. IT IS INTENDED FOR REFERENCE ONLY. THIS PLAN IS NOT INTENDED TO BE A DETAILED DESCRIPTION OF ALL REQUIRED WORK. PRIOR TO CONSTRUCTION, CONTRACTOR TO FIELD VERIFY ALL SITE AND BUILDING LAYOUT DIMENSIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCY IMMEDIATELY. DIMENSIONS HAVE NOT BEEN FULLY VERIFIED AND ARE SHOWN FOR GENERAL DEFINITION OF SCALE AND EXTENTS OF SCOPE WHERE SHOWN. ALL TREES ARE TO REMAIN AND WHERE ADJACENT TO BUILDING DEMOLITION, SHOULD BE PROTECTED FROM ALL DAMAGE, TYPICAL, UNLESS OTHERWISE NOTED - REFER TO CIVIL. REMOVAL OF BUILDINGS SHALL INCLUDE ENTIRE SITE BEING CLEARED DOWN TO SOIL, TYPICAL. DEMOLITION INCLUDES HAULING AND PROPER DISPOSAL - REFER TO SPECIFICATIONS. DEMOLITION INCLUDES REMOVAL OF ALL TRASH AND ABANDONED VEHICLES ON SITE COORDINATE REQUIREMENTS AND LOCATION OF THE DEMARCATION WITH THE LOCAL TELEPHONE COMPANY AND IT DEPARTMENT. ALL AREAS NOT NOTED FOR DEMOLITION ARE TO BE PROTECTED. MAINTAIN TEMPORARY POWER TO SITE - COORDINATE WITH OWNER AND UTILITY. REFER TO CIVIL UTILITY LOCATIONS AND SITE DEMOLITION SCOPE. CONTRACTOR TO FIELD LOCATE EXISTING BUILDING POTABLE WATER AND SANITARY SEWER UTILITIES AND CAP SERVICES. CONTRACTOR TO COORDINATE UTILITY DEMOLITION WITH THE ST. THOMAS WATER AND POWER AUTHORITY (WAPA) AND WASTE MANAGEMENT AUTHORITY (WMA) PRIOR TO CONSTRUCTION. CONTRACTOR TO USE CAUTION WHEN DEMOLISHING SEWER PIPE KNOWN TO RUN BELOW BUILDING FOUNDATION. USE ALTERNATE MEANS SUCH AS BY-PASS PUMPING IF NECESSARY TO ENSURE CONTINUATION OF FLOWS DURING CONSTRUCTION. REPAIR PIPE IMMEDIATELY IF IMPACTED DURING FIELD WORK. CONTRACTOR TO REFER TO CIVIL ENGINEER FOR REMOVAL AND REPLACEMENT OF EXISTING ELECTRICAL INFRASTRUCTURE WITHIN THE BUILDING PRIOR TO DEMOLITION. REFER TO SHEETS G005-G007 FOR PICTURES OF EXISTING CONDITIONS. EXISTING WALL TO REMAIN DEMOLITION SYMBOL LEGEND EXISTING WALL TO BE DEMOLISHED EXISTING DOOR TO BE DEMOLISHED NOT IN SCOPE / TO REMAIN DOH OLD MENTAL HEALTH BUILDING SCOPE DOH KNUD HANSEN TOWER SCOPE (FUTURE PHASE - SCOPE NOT NOTED IN THIS DRAWING SET) DHS KNUD HANSEN BUILDING SCOPE (FUTURE PHASE - SCOPE NOT NOTED IN THIS DRAWING SET) TEMPORARY CONSTRUCTION FENCING KEYPLAN REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Programming B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR TASK ORDER NUMBER G007 11/21/2025 JT TKB 1303 Hospital Ground, Knud Hansen Complex St. Thomas, US. Virgin Islands 00802 OLD MENTAL HEALTH BUILDING DEMOLITION AND PARKING LOT DEMOLITION REFERENCE PHOTOS 60% DEMOLITION DRAWINGS 470-21-34 2020-03 10.15.25 1 4 5 3 2 4 5 3 1 2 No. Description Date 9713 ESTATE THOMAS, BUILDING 1, SUITE 200 ST. THOMAS, USVI 00802 ST. THOMAS OLD MENTAL HEALTH BUILDING PREPARED FOR: SPRINGLINE ARCHITECTS Prepared By REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Schematic B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR PROJECT NUMBER 12.15.2025 NW CT 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 OLD MENTAL HEALTH BUILDING COVER SHEET 470-21-34 2020-03 No. Description Date PERMIT SET C0.00 REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Schematic B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR PROJECT NUMBER 12.15.2025 NW CT 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 OLD MENTAL HEALTH BUILDING 470-21-34 2020-03 No. Description Date C0.01 GENERAL NOTES REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Schematic B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR PROJECT NUMBER 12.15.2025 NW CT 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 OLD MENTAL HEALTH BUILDING 470-21-34 2020-03 No. Description Date EXISTING CONDITIONS SURVEY C0.02 REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Schematic B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR PROJECT NUMBER 12.15.2025 NW CT 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 OLD MENTAL HEALTH BUILDING 470-21-34 2020-03 No. Description Date DEMOLITION AND EROSION CONTROL PLAN C0.90 20 20 13 20 4 7 4 9 C1.00 REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Schematic B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR PROJECT NUMBER 12.15.2025 NW CT 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 OLD MENTAL HEALTH BUILDING 470-21-34 2020-03 No. Description Date SITE PLAN SHARED SURFACE PARKING (TOTAL = 137 spaces) REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Schematic B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR PROJECT NUMBER 12.15.2025 NW CT 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 OLD MENTAL HEALTH BUILDING 470-21-34 2020-03 No. Description Date GRADING PLAN C2.00 SHARED SURFACE PARKING (TOTAL = 137 spaces) REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Schematic B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR PROJECT NUMBER 12.15.2025 NW CT 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 OLD MENTAL HEALTH BUILDING 470-21-34 2020-03 No. Description Date DRAINAGE PLAN C2.50 REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Schematic B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR PROJECT NUMBER 12.15.2025 NW CT 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 OLD MENTAL HEALTH BUILDING 470-21-34 2020-03 No. Description Date UTILITY PLAN C3.00 REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Schematic B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR PROJECT NUMBER 12.15.2025 NW CT 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 OLD MENTAL HEALTH BUILDING 470-21-34 2020-03 No. Description Date C4.00 DETAILS REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Schematic B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR PROJECT NUMBER 12.15.2025 NW CT 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 OLD MENTAL HEALTH BUILDING 470-21-34 2020-03 No. Description Date C4.01 DETAILS NOTES: 1. INITIAL BACKFILL: SELECT COMMON FILL COMPACTED TO 95% (98% UNDER PAVEMENT) OF THE MAXIMUM DENSITY AS PER AASHTO T-180. 2. TRENCH BACKFILL: COMMON FILL COMPACTED TO 95% (98% UNDER PAVEMENT) OF THE MAXIMUM DENSITY AS PER AASHTO T-180. 3. TYPE A BEDDING MATERIAL SHALL CONFORM TO FDOT NO. 57 AGGREGATE. 4. 15" MAX. (12" MIN.) FOR PIPE DIAMETER LESS THAN 24" AND 24" MAX (12" MIN) FOR PIPE DIAMETER 24" AND LARGER. 5. WATER SHALL NOT BE PERMITTED IN THE TRENCH DURING CONSTRUCTION. 6. ALL PIPE TO BE INSTALLED WITH BELL FACING UPSTREAM TO THE DIRECTION OF THE FLOW. 7. BEDDING DEPTH SHALL BE 4" MINIMUM FOR PIPE DIAMETER UP TO 12" AND 6" MINIMUM FOR PIPE DIAMETER 16" AND LARGER. 8. DEPTH FOR REMOVAL OF UNSUITABLE MATERIAL SHALL GOVERN DEPTH OF BEDDING ROCK BELOW THE PIPE. UTILITIES SHALL DETERMINE IN THE FIELD REQUIRED REMOVAL OF UNSUITABLE MATERIAL TO REACH SUITABLE FOUNDATION. 9. FINAL RESTORATION IN IMPROVED AREAS SHALL BE IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS OF GOVERNING AGENCIES. NOTES: 1. INITIAL BACKFILL AND HAUNCHING: SELECT COMMON FILL COMPACTED TO 95% (98% UNDER PAVEMENT) OF THE MAXIMUM DENSITY AS PER AASHTO T-180. 2. TRENCH BACKFILL: COMMON FILL COMPACTED TO 95% (98% UNDER PAVEMENT) OF THE MAXIMUM DENSITY AS PER AASHTO T-180. 3. PIPE BEDDING UTILIZING SELECT COMMON FILL OR BEDDING ROCK IN ACCORDANCE WITH TYPE A BEDDING AND TRENCHING DETAIL MAY BE REQUIRED AS DIRECTED BY UTILITIES. 4. 15" MAX. (12" MIN.) FOR PIPE DIAMETER LESS THAN 24" AND 24" MAX (12" MIN) FOR PIPE DIAMETER 24" AND LARGER. 5. WATER SHALL NOT BE PERMITTED IN THE TRENCH DURING CONSTRUCTION. 6. ALL PIPE TO BE INSTALLED WITH BELL FACING UPSTREAM TO THE DIRECTION OF THE FLOW. 7. FINAL RESTORATION IN IMPROVED AREAS SHALL BE IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS OF GOVERNING AGENCIES. HORIZONTAL SEPARATION REQUIREMENTS (NOTES 1 & 2) PROPOSED UTILITY POTABLE WATER RECLAIMED WATER MAIN WASTEWATER FORCEMAIN SANITARY SEWER STORM SEWER STRUCTURAL FOUNDATION, WALLS, ETC. (SEE NOTE 4) 4"-12" 16"-UP 4"-12" 16"-UP 4"-12" 16"-UP ALL SIZES ALL SIZES ALL SIZES POTABLE WATER 4"-12" 3' 5' 3' 5' 6' 6' 6' 3' 10' 16"-UP 5' 5' 5' 5' 6' 6' 6' 5' 15' RECLAIMED WATER MAIN 4"-12" 3' 5' 3' 5' 3' 5' 3' 3' 10' 16"-UP 5' 5' 5' 5' 5' 5' 5' 5' 15' WASTEWATER FORCEMAIN 4"-12" 6' 6' 3' 5' 3' 5' 3' 3' 10' 16"-UP 6' 6' 5' 5' 5' 5' 5' 5' 15' SANITARY SEWER ALL SIZES 6' 6' 3' 5' 3' 5' 3' 5' VARIES PER DEPTH NOTES: 1. DISTANCES GIVEN ARE FROM OUTSIDE OF PIPE TO OUTSIDE OF PIPE. 2. THIS SEPARATION REQUIREMENT IS TO PROVIDE ACCESSIBILITY FOR CONSTRUCTION AND MAINTENANCE. FOR PIPES INSTALLED AT GREATER DEPTHS THAN THE MINIMUM DESIGN STANDARDS, PROVIDE AN ADDITIONAL FOOT OF SEPARATION FOR EACH ADDITIONAL FOOT OF DEPTH. 3. NO WATER PIPE SHALL PASS THROUGH OR COME IN CONTACT WITH ANY PART OF SANITARY OR STORM WATER MANHOLE OR STRUCTURE. 4. ADDITIONAL SEPARATION SHALL BE REQUIRED BY UTILITIES FOR CONSTRUCTION OF, INCLUDING, BUT NOT LIMITED TO: LIVE LOADS, MULTI-STORY COMMERCIAL BUILDINGS, SUPERSTRUCTURES, EMBANKMENTS, RETAINING WALLS, BRIDGES, RAILROADS, HIGH VOLTAGE TRANSMISSION MAINS, GAS MAINS, ETC. VERTICAL SEPARATION REQUIREMENTS (NOTES 1 & 2) PROPOSED UTILITY POTABLE WATER RECLAIMED WATER MAIN WASTEWATER FORCEMAIN SANITARY SEWER STORM SEWER (NOTE 3) POTABLE WATER 12" 12" 12" / 18" 12" / 18" 12" / 18" RECLAIMED WATER MAIN 12" 12" 12" 12" 12" / 18" WASTEWATER FORCEMAIN 12" 12" 12" 12" 12" / 18" SANITARY SEWER 12" / 18" 12" 12" 12" 12" / 18" NOTES: 1. DISTANCES GIVEN ARE FROM OUTSIDE OF PIPE TO OUTSIDE OF PIPE. 2. THIS SEPARATION REQUIREMENT IS TO PROVIDE ACCESSIBILITY FOR CONSTRUCTION AND MAINTENANCE. 3. THE 18-IN SEPARATION REQUIREMENT APPLIES WHEN THE STORM PIPE OR SANITARY SEWER CROSSES ABOVE THE UTILITY MAIN, AND WHEN THE STORM PIPE HAS A DIAMETER EQUAL TO OR GREATER THAN 24-IN. OTHERWISE, THE REQUIRED SEPARATION IS 12-IN. 4. NO WATER PIPE SHALL PASS THROUGH OR COME IN CONTACT WITH ANY PART OF SANITARY OR STORM WATER MANHOLE OR STRUCTURE. 5. JOINT SPACING AT CROSSING SHALL COMPLY WITH THE MINIMUM FDEP SEPARATION REQUIREMENTS OUTLINED IN 62-555.314, F.A.C. REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Schematic B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR PROJECT NUMBER 12.15.2025 NW CT 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 OLD MENTAL HEALTH BUILDING 470-21-34 2020-03 No. Description Date C4.02 DETAILS NOTE: 1. LOCKING LIDS ARE REQUIRED ON ALL VALVE BOXES. TYPICAL LOCKING BOLT REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Schematic B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR PROJECT NUMBER 12.15.2025 NW CT 1303 Hospital Ground St. Thomas, US. Virgin Islands 00802 OLD MENTAL HEALTH BUILDING 470-21-34 2020-03 No. Description Date C4.03 DETAILS UP DN DN DN UP DN X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X D3 D201 D201 A1 D201 C1 D201 A3 D201 C3 3-STORY DOH OLD MENTAL HEALTH BUILDING TO BE DEMOLISHED 1-STORY DOH BUILDING TO REMAIN DOH WIC BUILDING TO REMAIN 3-STORY DHS KNUD HANSEN BUILDING TO REMAIN HOSPITAL GROUND ROAD OLD HOSPITAL ROAD HOSPITAL GROUND ROAD 4-STORY DOH KNUD HANSEN TOWER BUILDING TO REMAIN DOH JOHN S. MOOREHEAD COMPLEX TO REMAIN 11 12 14 15 08 01 05 11 06 20 1-STORY HISTORIC BUILDING TO REMAIN 1-STORY HISTORIC BUILDING TO REMAIN 08 03 16 17 17 20 20 22 22 PHASE 1 PHASE 2 13 11 11 OPTION FOR FENCING TO KEEP BETHLEHEM HOUSE ACCESS OPTIONS FOR AREA OF SAFE DISPERSAL = 6SF PER OCC REQ. 380 SF 380 SF KEYPLAN GENERAL DEMOLITION NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. THIS PLAN IS A GENERAL REPRESENTATION OF EXISTING CONDITIONS. IT IS INTENDED FOR REFERENCE ONLY. THIS PLAN IS NOT INTENDED TO BE A DETAILED DESCRIPTION OF ALL REQUIRED WORK. PRIOR TO CONSTRUCTION, CONTRACTOR TO FIELD VERIFY ALL SITE AND BUILDING LAYOUT DIMENSIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCY IMMEDIATELY. DIMENSIONS HAVE NOT BEEN FULLY VERIFIED AND ARE SHOWN FOR GENERAL DEFINITION OF SCALE AND EXTENTS OF SCOPE WHERE SHOWN. ALL TREES ARE TO REMAIN AND WHERE ADJACENT TO BUILDING DEMOLITION, SHOULD BE PROTECTED FROM ALL DAMAGE, TYPICAL, UNLESS OTHERWISE NOTED - REFER TO CIVIL. REMOVAL OF BUILDINGS SHALL INCLUDE ENTIRE SITE BEING CLEARED DOWN TO SOIL, TYPICAL. DEMOLITION INCLUDES HAULING AND PROPER DISPOSAL - REFER TO SPECIFICATIONS. DEMOLITION INCLUDES REMOVAL OF ALL TRASH AND ABANDONED VEHICLES ON SITE COORDINATE REQUIREMENTS AND LOCATION OF THE DEMARCATION WITH THE LOCAL TELEPHONE COMPANY AND IT DEPARTMENT. ALL AREAS NOT NOTED FOR DEMOLITION ARE TO BE PROTECTED. MAINTAIN TEMPORARY POWER TO SITE - COORDINATE WITH OWNER AND UTILITY. REFER TO CIVIL UTILITY LOCATIONS AND SITE DEMOLITION SCOPE. CONTRACTOR TO FIELD LOCATE EXISTING BUILDING POTABLE WATER AND SANITARY SEWER UTILITIES AND CAP SERVICES. CONTRACTOR TO COORDINATE UTILITY DEMOLITION WITH THE ST. THOMAS WATER AND POWER AUTHORITY (WAPA) AND WASTE MANAGEMENT AUTHORITY (WMA) PRIOR TO CONSTRUCTION. CONTRACTOR TO USE CAUTION WHEN DEMOLISHING SEWER PIPE KNOWN TO RUN BELOW BUILDING FOUNDATION. USE ALTERNATE MEANS SUCH AS BY-PASS PUMPING IF NECESSARY TO ENSURE CONTINUATION OF FLOWS DURING CONSTRUCTION. REPAIR PIPE IMMEDIATELY IF IMPACTED DURING FIELD WORK. CONTRACTOR TO REFER TO CIVIL ENGINEER FOR REMOVAL AND REPLACEMENT OF EXISTING ELECTRICAL INFRASTRUCTURE WITHIN THE BUILDING PRIOR TO DEMOLITION. REFER TO SHEETS G005-G007 FOR PICTURES OF EXISTING CONDITIONS. EXISTING WALL TO REMAIN DEMOLITION SYMBOL LEGEND EXISTING WALL TO BE DEMOLISHED EXISTING DOOR TO BE DEMOLISHED NOT IN SCOPE / TO REMAIN DOH OLD MENTAL HEALTH BUILDING SCOPE DOH KNUD HANSEN TOWER SCOPE (FUTURE PHASE - SCOPE NOT NOTED IN THIS DRAWING SET) DHS KNUD HANSEN BUILDING SCOPE (FUTURE PHASE - SCOPE NOT NOTED IN THIS DRAWING SET) TEMPORARY CONSTRUCTION FENCING NORTH REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Programming B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR TASK ORDER NUMBER D001 11/21/2025 KB HK 1303 Hospital Ground, Knud Hansen Complex St. Thomas, US. Virgin Islands 00802 OLD MENTAL HEALTH BUILDING DEMOLITION AND PARKING LOT DEMOLITION SITE PLAN 60% DEMOLITION DRAWINGS 470-21-34 2020-03 10.15.25 3/64" = 1'-0" D001 SITE PLAN - DEMOLITION A1 # KEYNOTES - DEMOLITION # DESCRIPTION 01 DEMOLISH EXISTING BUILDING TO PROVIDED EXTENTS INCLUDING ROOF STRUCTURE, EXTERIOR AND INTERIOR WALLS, WINDOWS, DOORS, FLOORS AND FLOOR SLABS, ALL BUILDING UTILITIES: PIPING, DUCTWORK, ELECTRICAL, FIXTURES AND DEBRIS DOWN TO SOIL (TYPICAL) 03 DEMOLISH EXISTING RETAINING WALL; CONTRACTOR IS RESPONSIBLE FOR TEMPORARY SHORING OR STABILIZATION OF GRADE UNTIL PERMANENT CONSTRUCTION HAS BEEN PLACED. 05 MAINTAIN EXISTING GENERATOR AND ENCLOSURE DURING PHASE 1 06 DEMOLISH EXISTING CISTERN; FILL WITH CLEAN DIRT AS INDICATED ON CIVIL PLANS 08 DEMOLISH EXISTING VEGETATION AND TREES AS SHOWN 11 MAINTAIN AND PROTECT EXISTING TREE 12 HISTORIC WALL TO REMAIN; CONTRACTOR IS REQUIRED TO STABILIZE AND PROTECT ALL PORTIONS TO REMAIN 13 HISTORIC STRUCTURE TO REMAIN; CONTRACTOR IS RESPONSIBLE FOR STABILIZATION AND PROTECTION OF ALL ELEMENTS DURING DEMOLITION. 14 MAINTAIN EXISTING STRUCTURE; CONTRACTOR IS RESPONSIBLE FOR STABILIZATION AND PROTECTION OF STRUCTURE DURING DEMOLITION 15 MAINTAIN EXISTING RETAINING WALL 16 DEMOLISH ALL EXISTING PERIMETER FENCING AND GATES AS INDICATED; REFER TO CIVIL 17 DEMOLISH EXISTING UTILITY POLE; REFER TO CIVIL 20 SECURE SITE PRIOR TO ANY DEMOLITION ACTIVITIES WITH 8' TALL CHAIN LINK FENCING WITH INTEGRATED WIND AND VISUAL BARRIER. 22 WHERE DHS BUILDING & HISTORIC BUILDING ABUT OLD MENTAL HEALTH BUILDING DEMOLITION SCOPE, CONTRACTOR TO USE SELECTIVE DEMOLITION, DELEGATED STRUCTURAL ENGINEERING, AND OTHER MEANS AND METHODS TO ENSURE DEMOLITION OF OLD MENTAL HEALTH BUILDLING DOES NOT COMPROMISE THE STRUCTURAL INTEGRITY OF THE DHS BUILDING AND HISTORIC STRUCTURE TO REMAIN. No. Description Date X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X NORTH CISTERN 8,706.6 SF BASEMENT 2,955 SF 01 01 01 D3 D201 D201 A1 D201 A3 D201 C3 144' - 8" 60' - 2" DHS UNDER SEPARATE CONTRACT BELOW GRADE BELOW GRADE 06 06 PARKING AREA GENERAL DEMOLITION NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. THIS PLAN IS A GENERAL REPRESENTATION OF EXISTING CONDITIONS. IT IS INTENDED FOR REFERENCE ONLY. THIS PLAN IS NOT INTENDED TO BE A DETAILED DESCRIPTION OF ALL REQUIRED WORK. PRIOR TO CONSTRUCTION, CONTRACTOR TO FIELD VERIFY ALL SITE AND BUILDING LAYOUT DIMENSIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCY IMMEDIATELY. DIMENSIONS HAVE NOT BEEN FULLY VERIFIED AND ARE SHOWN FOR GENERAL DEFINITION OF SCALE AND EXTENTS OF SCOPE WHERE SHOWN. ALL TREES ARE TO REMAIN AND WHERE ADJACENT TO BUILDING DEMOLITION, SHOULD BE PROTECTED FROM ALL DAMAGE, TYPICAL, UNLESS OTHERWISE NOTED - REFER TO CIVIL. REMOVAL OF BUILDINGS SHALL INCLUDE ENTIRE SITE BEING CLEARED DOWN TO SOIL, TYPICAL. DEMOLITION INCLUDES HAULING AND PROPER DISPOSAL - REFER TO SPECIFICATIONS. DEMOLITION INCLUDES REMOVAL OF ALL TRASH AND ABANDONED VEHICLES ON SITE COORDINATE REQUIREMENTS AND LOCATION OF THE DEMARCATION WITH THE LOCAL TELEPHONE COMPANY AND IT DEPARTMENT. ALL AREAS NOT NOTED FOR DEMOLITION ARE TO BE PROTECTED. MAINTAIN TEMPORARY POWER TO SITE - COORDINATE WITH OWNER AND UTILITY. REFER TO CIVIL UTILITY LOCATIONS AND SITE DEMOLITION SCOPE. CONTRACTOR TO FIELD LOCATE EXISTING BUILDING POTABLE WATER AND SANITARY SEWER UTILITIES AND CAP SERVICES. CONTRACTOR TO COORDINATE UTILITY DEMOLITION WITH THE ST. THOMAS WATER AND POWER AUTHORITY (WAPA) AND WASTE MANAGEMENT AUTHORITY (WMA) PRIOR TO CONSTRUCTION. CONTRACTOR TO USE CAUTION WHEN DEMOLISHING SEWER PIPE KNOWN TO RUN BELOW BUILDING FOUNDATION. USE ALTERNATE MEANS SUCH AS BY-PASS PUMPING IF NECESSARY TO ENSURE CONTINUATION OF FLOWS DURING CONSTRUCTION. REPAIR PIPE IMMEDIATELY IF IMPACTED DURING FIELD WORK. CONTRACTOR TO REFER TO CIVIL ENGINEER FOR REMOVAL AND REPLACEMENT OF EXISTING ELECTRICAL INFRASTRUCTURE WITHIN THE BUILDING PRIOR TO DEMOLITION. REFER TO SHEETS G005-G007 FOR PICTURES OF EXISTING CONDITIONS. EXISTING WALL TO REMAIN DEMOLITION SYMBOL LEGEND EXISTING WALL TO BE DEMOLISHED EXISTING DOOR TO BE DEMOLISHED NOT IN SCOPE / TO REMAIN DOH OLD MENTAL HEALTH BUILDING SCOPE DOH KNUD HANSEN TOWER SCOPE (FUTURE PHASE - SCOPE NOT NOTED IN THIS DRAWING SET) DHS KNUD HANSEN BUILDING SCOPE (FUTURE PHASE - SCOPE NOT NOTED IN THIS DRAWING SET) TEMPORARY CONSTRUCTION FENCING FIRST FLOOR 11,300 SF DHS UNDER SEPARATE CONTRACT PARKING LOT PARKING LOT D3 D201 D201 A1 D201 C1 D201 A3 D201 C3 MECH. RM 273 SF STORAGE AREA 965 SF 01 01 15' - 3" 36' - 5" 25' - 2 1/2" 8' - 7" 144' - 4 3/4" 36' - 4" 60' - 2" 13 04 06 02 02 01 01 04 02 17' - 9" 11 22 22 22 22 KEYPLAN SECOND FLOOR 11,250 SF BALCONY BALCONY DHS UNDER SEPARATE CONTRACT 01 D3 D201 D201 A1 D201 C1 D201 A3 D201 C3 01 144' - 5" 36' - 3 3/4" 60' - 2" 5' - 6" 01 13 22 22 22 18 18 18 ROOF 6,488 SF ELEV. / STAIR SHAFT TO BE DEMO ELEV / STAIR SHAFT TO BE DEMO D3 D201 D201 A1 D201 A3 01 18 22 REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Programming B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR TASK ORDER NUMBER D101 11/21/2025 KB RCC 1303 Hospital Ground, Knud Hansen Complex St. Thomas, US. Virgin Islands 00802 OLD MENTAL HEALTH BUILDING DEMOLITION AND PARKING LOT DEMOLITION FLOOR PLANS 60% DEMOLITION DRAWINGS 470-21-34 2020-03 10.15.25 1/16" = 1'-0" D101 BASEMENT FLOOR PLAN - DEMOLITION A1 1/16" = 1'-0" D101 1ST FLOOR PLAN - DEMOLITION C1 1/16" = 1'-0" D101 2ND FLOOR PLAN - DEMOLITION A3 1/16" = 1'-0" D101 ROOF PLAN - DEMOLITION D3 # KEYNOTES - DEMOLITION # DESCRIPTION 01 DEMOLISH EXISTING BUILDING TO PROVIDED EXTENTS INCLUDING ROOF STRUCTURE, EXTERIOR AND INTERIOR WALLS, WINDOWS, DOORS, FLOORS AND FLOOR SLABS, ALL BUILDING UTILITIES: PIPING, DUCTWORK, ELECTRICAL, FIXTURES AND DEBRIS DOWN TO SOIL (TYPICAL) 02 DEMOLISH EXISTING SIDEWALKS, STAIRS, RAMPS, AND RAILINGS TO GRADE 04 DEMOLISH EXISTING ASPHALT PAVEMENT AS INDICATED ON CIVIL PLANS 06 DEMOLISH EXISTING CISTERN; FILL WITH CLEAN DIRT AS INDICATED ON CIVIL PLANS 11 MAINTAIN AND PROTECT EXISTING TREE 13 HISTORIC STRUCTURE TO REMAIN; CONTRACTOR IS RESPONSIBLE FOR STABILIZATION AND PROTECTION OF ALL ELEMENTS DURING DEMOLITION. 18 DEMOLISH EXISTING RAILING AT BALCONY 22 WHERE DHS BUILDING & HISTORIC BUILDING ABUT OLD MENTAL HEALTH BUILDING DEMOLITION SCOPE, CONTRACTOR TO USE SELECTIVE DEMOLITION, DELEGATED STRUCTURAL ENGINEERING, AND OTHER MEANS AND METHODS TO ENSURE DEMOLITION OF OLD MENTAL HEALTH BUILDLING DOES NOT COMPROMISE THE STRUCTURAL INTEGRITY OF THE DHS BUILDING AND HISTORIC STRUCTURE TO REMAIN. No. Description Date X X X DOH OMH BASEMENT 59' - 11 3/4" DOH OMH 1ST FLOOR 69' - 6 3/4" DOH OMH B.O. ROOF 91' - 7 3/4" DOH OMH 2ND FLOOR 80' - 6 3/4" 0" EXISTING CISTERN EXISTING STAIR/ ELEVATOR SHAFTS DOH OMH T.O. STAIR 100' - 6 3/4" 06 01 01 01 01 DOH OMH BASEMENT 59' - 11 3/4" DOH OMH 1ST FLOOR 69' - 6 3/4" DOH OMH B.O. ROOF 91' - 7 3/4" DOH OMH 2ND FLOOR 80' - 6 3/4" DOH OMH T.O. STAIR 100' - 6 3/4" 01 01 01 13 DOH OMH BASEMENT 59' - 11 3/4" DOH OMH 1ST FLOOR 69' - 6 3/4" DOH OMH B.O. ROOF 91' - 7 3/4" DOH OMH 2ND FLOOR 80' - 6 3/4" DOH OMH T.O. STAIR 100' - 6 3/4" 01 01 01 01 01 10' - 1" 22 GENERAL DEMOLITION NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. THIS PLAN IS A GENERAL REPRESENTATION OF EXISTING CONDITIONS. IT IS INTENDED FOR REFERENCE ONLY. THIS PLAN IS NOT INTENDED TO BE A DETAILED DESCRIPTION OF ALL REQUIRED WORK. PRIOR TO CONSTRUCTION, CONTRACTOR TO FIELD VERIFY ALL SITE AND BUILDING LAYOUT DIMENSIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCY IMMEDIATELY. DIMENSIONS HAVE NOT BEEN FULLY VERIFIED AND ARE SHOWN FOR GENERAL DEFINITION OF SCALE AND EXTENTS OF SCOPE WHERE SHOWN. ALL TREES ARE TO REMAIN AND WHERE ADJACENT TO BUILDING DEMOLITION, SHOULD BE PROTECTED FROM ALL DAMAGE, TYPICAL, UNLESS OTHERWISE NOTED - REFER TO CIVIL. REMOVAL OF BUILDINGS SHALL INCLUDE ENTIRE SITE BEING CLEARED DOWN TO SOIL, TYPICAL. DEMOLITION INCLUDES HAULING AND PROPER DISPOSAL - REFER TO SPECIFICATIONS. DEMOLITION INCLUDES REMOVAL OF ALL TRASH AND ABANDONED VEHICLES ON SITE COORDINATE REQUIREMENTS AND LOCATION OF THE DEMARCATION WITH THE LOCAL TELEPHONE COMPANY AND IT DEPARTMENT. ALL AREAS NOT NOTED FOR DEMOLITION ARE TO BE PROTECTED. MAINTAIN TEMPORARY POWER TO SITE - COORDINATE WITH OWNER AND UTILITY. REFER TO CIVIL UTILITY LOCATIONS AND SITE DEMOLITION SCOPE. CONTRACTOR TO FIELD LOCATE EXISTING BUILDING POTABLE WATER AND SANITARY SEWER UTILITIES AND CAP SERVICES. CONTRACTOR TO COORDINATE UTILITY DEMOLITION WITH THE ST. THOMAS WATER AND POWER AUTHORITY (WAPA) AND WASTE MANAGEMENT AUTHORITY (WMA) PRIOR TO CONSTRUCTION. CONTRACTOR TO USE CAUTION WHEN DEMOLISHING SEWER PIPE KNOWN TO RUN BELOW BUILDING FOUNDATION. USE ALTERNATE MEANS SUCH AS BY-PASS PUMPING IF NECESSARY TO ENSURE CONTINUATION OF FLOWS DURING CONSTRUCTION. REPAIR PIPE IMMEDIATELY IF IMPACTED DURING FIELD WORK. CONTRACTOR TO REFER TO CIVIL ENGINEER FOR REMOVAL AND REPLACEMENT OF EXISTING ELECTRICAL INFRASTRUCTURE WITHIN THE BUILDING PRIOR TO DEMOLITION. REFER TO SHEETS G005-G007 FOR PICTURES OF EXISTING CONDITIONS. EXISTING WALL TO REMAIN DEMOLITION SYMBOL LEGEND EXISTING WALL TO BE DEMOLISHED EXISTING DOOR TO BE DEMOLISHED NOT IN SCOPE / TO REMAIN DOH OLD MENTAL HEALTH BUILDING SCOPE DOH KNUD HANSEN TOWER SCOPE (FUTURE PHASE - SCOPE NOT NOTED IN THIS DRAWING SET) DHS KNUD HANSEN BUILDING SCOPE (FUTURE PHASE - SCOPE NOT NOTED IN THIS DRAWING SET) TEMPORARY CONSTRUCTION FENCING DOH OMH BASEMENT 59' - 11 3/4" DOH OMH 1ST FLOOR 69' - 6 3/4" DOH OMH B.O. ROOF 91' - 7 3/4" DOH OMH 2ND FLOOR 80' - 6 3/4" DOH OMH T.O. STAIR 100' - 6 3/4" EXISTING STAIR 01 01 01 01 DHS DEMO ON SEPARATE CONTRACT 01 01 DOH OMH BASEMENT 59' - 11 3/4" DOH OMH 1ST FLOOR 69' - 6 3/4" DOH OMH B.O. ROOF 91' - 7 3/4" DOH OMH 2ND FLOOR 80' - 6 3/4" DOH OMH T.O. STAIR 100' - 6 3/4" EXISTING HISTORICAL BUILDING TO REMAIN DHS DEMO ON SEPARATE CONTRACT 01 01 01 13 22 KEYPLAN REVISIONS: DRAWN BY: CHECKED BY: DATE: NOVUS JOB NUMBER SHEET NUMBER A B C D E ALL INFORMATION CONTAINED HEREIN IS THE PROPERTY OF SPRINGLINE ARCHITECTS L.L.C. THE CONCEPTS, IDEAS, DESIGNS AND DETAILS AS SHOWN ON THE DOCUMENTS WERE CREATED, DEVELOPED, AND PRESENTED FOR USE ON THIS SPECIFIC PROJECT AND SHALL NOT BE REUSED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN CONSENT OF SPRINGLINE ARCHITECTS L.L.C. THE OWNER SHALL BE PERMITTED TO RETAIN COPIES FOR INFORMATION AND REFERENCE PURPOSES ONLY. 1 2 3 4 5 1 2 3 4 5 NOT FOR CONSTRUCTION INPROGRESS DOCUMENTS FOR INTERIM REVIEW ONLY. NOT FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. SUBMISSIONS: Ref Description Date A Programming B 60% CDs C 90% CDs D 100% CDs E 30% CDs ODR TASK ORDER NUMBER D201 11/21/2025 KB RCC 1303 Hospital Ground, Knud Hansen Complex St. Thomas, US. Virgin Islands 00802 OLD MENTAL HEALTH BUILDING DEMOLITION AND PARKING LOT DEMOLITION ELEVATIONS & SECTION 60% DEMOLITION DRAWINGS 470-21-34 2020-03 10.15.25 1/16" = 1'-0" D201 DEMOLITION BUILDING SECTION D3 1/16" = 1'-0" D201 DEMOLITION ELEVATION - NORTH A1 1/16" = 1'-0" D201 DEMOLITION ELEVATION - SOUTH C1 1/16" = 1'-0" D201 DEMOLITION ELEVATION - EAST A3 1/16" = 1'-0" D201 DEMOLITION ELEVATION - WEST C3 # KEYNOTES - DEMOLITION # DESCRIPTION 01 DEMOLISH EXISTING BUILDING TO PROVIDED EXTENTS INCLUDING ROOF STRUCTURE, EXTERIOR AND INTERIOR WALLS, WINDOWS, DOORS, FLOORS AND FLOOR SLABS, ALL BUILDING UTILITIES: PIPING, DUCTWORK, ELECTRICAL, FIXTURES AND DEBRIS DOWN TO SOIL (TYPICAL) 06 DEMOLISH EXISTING CISTERN; FILL WITH CLEAN DIRT AS INDICATED ON CIVIL PLANS 13 HISTORIC STRUCTURE TO REMAIN; CONTRACTOR IS RESPONSIBLE FOR STABILIZATION AND PROTECTION OF ALL ELEMENTS DURING DEMOLITION. 22 WHERE DHS BUILDING & HISTORIC BUILDING ABUT OLD MENTAL HEALTH BUILDING DEMOLITION SCOPE, CONTRACTOR TO USE SELECTIVE DEMOLITION, DELEGATED STRUCTURAL ENGINEERING, AND OTHER MEANS AND METHODS TO ENSURE DEMOLITION OF OLD MENTAL HEALTH BUILDLING DOES NOT COMPROMISE THE STRUCTURAL INTEGRITY OF THE DHS BUILDING AND HISTORIC STRUCTURE TO REMAIN. No. Description Date